Heat recovery and low humidity roof top type air conditioning
Roof top air conditioning unit Description:
1. Air cooled rooftop air conditioner.
2. Cooling capacity: 8kw to 90kw, a variety of choices.
3. High external pressure.
4. Applicable to residential and commercial buildings, hotels, and scientific research units, factories and enterprises and so on.
Feature:
1. Evaporator: Type Inner grooved copper tube and aluminum fin
2. Fin Type 5* :Slotted fin hydrophilic aluminum fin
3. Condenser: Type Inner grooved copper tube and aluminum fin
4. Fin Type 5* :Rippled hydrophilic aluminum fin
5. Condenser Fan Type: Low noise axial type
Technical data:
GT-WKR Series-Roof Top AH Specifiaction 1 |
Model GT-WKR- |
10 |
15 |
18 |
20 |
25 |
30 |
35 |
Specification |
Cooling capacity 1* |
kW |
10.5 |
15.0 |
18.5 |
21.0 |
26.3 |
29.8 |
35.0 |
Heating capacity 2* |
kW |
11.5 |
15.9 |
19.5 |
22.1 |
27.6 |
32.6 |
37.1 |
Supply air 3* |
m3/h |
1800 |
2400 |
2900 |
3500 |
4500 |
5000 |
5800 |
Static pressure 3* |
Pa |
100 |
150 |
150 |
180 |
200 |
250 |
250 |
Noise 4* |
dB(A) |
60 |
60 |
62 |
62 |
65 |
65 |
68 |
Power |
3N-380V-50Hz |
Total capacity |
3.9 |
5.74 |
7.0 |
8.27 |
9.96 |
11.0 |
14.15 |
Color |
White |
ooling system |
Compressor |
Type |
Efficient scroll closed |
Quantity |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
Supply air fan |
Type |
Low noise centrifugal type |
Capacity |
kW |
0.37 |
0.55 |
0.75 |
0.75 |
1.1 |
1.5 |
2.2 |
Evaporator |
Type |
Inner grooved copper tube and aluminum fin |
Fin type 5* |
Slotted fin hydrophilic aluminum fin |
Condenser |
Type |
Inner grooved copper tube and aluminum fin |
Fin type 5* |
Rippled hydrophilic aluminum fin |
Condenser fan |
Type |
Low noise axial type |
Quantity |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
Refrigerant |
Refrigerant |
R22/R407C |
Refrigerant control |
External balance type thermal expansion valve |
Air filter |
Initially effect plate filter |
Dimensions |
L |
mm |
1400 |
1400 |
1600 |
1600 |
1850 |
1850 |
2200 |
W |
mm |
1050 |
1050 |
1200 |
1200 |
1400 |
1400 |
1800 |
H |
mm |
1050 |
1050 |
1050 |
1050 |
1200 |
1200 |
1520 |
Weight |
kg |
200 |
230 |
260 |
300 |
550 |
600 |
850 |
1. Cooling condition: Indoor dry bulb/wet bulb:29/19ºC,Outdoor dry bulb/wet bulb:46/24ºC
2. Heating condition:Indoor dry bulb/wet bulb:20/-ºC;outdoor dry bulb/wet bulb:7/6ºC;
3. The air volume and static pressure`s specification in the table is standard, and can be designable.
4. Noise data is measured in the front of the units when cooling under the standard air volume.
5. Fin type and material can be designable.
The features of rooftop packaged unit:
Cooling Capacity: Standard Unit from 3 ton (7KW) to 350 ton (105KW).
High efficiency- provided by the Anti-vibration mounting scroll compressor
Weather proof
Quiet operation-With low-noise fan motor and hermetic scroll compressor
with sound insulation system.
Intelligent control-Parameters of unit are monitored and adjusted by
microcomputer system.
Safety and reliability -Complete unit control function, multi protection, safe
and reliable operation.
Less space-Super thin indoor unit, high static pressure heads making
distant Blowing realized.
Meiling (Ms.)