Climate Control Fluid Coolers with Epoxy Coating Fin for Immersion Cooling Solution
Immersion Cooling Solution fluid cooler Features
- High efficiency heat exchanger: capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany
- Fan: only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw.Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Air separator for each fan.
- We facilitate you to have a long lasting and low maintenance operation. Durable material and rigid enclosure with hard gloss powder coated finish. Protective enclosure for both manifolds and U-bends. Unit design for outdoor installation. 100% leakage tested at 31bar.
Immersion Cooling Solution fluid cooler design Options:
* Coil design refrigerant: water, oil, glycol, CO2, BC888, shell S5X, S3X,
* Multiple circuits.
* Sub-cooling circuits.
* Stainless steel or aluminum casing.
* Coated aluminum or copper fins.
* Explosion ploof motor.
* Customized fin spacing.
Shenglin Software design for fluid cooler:
* Design and Heat transfer technology
* Advanced designing software
* Flexibility and Quick - Trial Production
adiabatic system design:
Immersion Cooling Solution fluid cooler Application:
Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, smelting, server immersion cooling, data center liquid cooling, dielectric liquid cooling, single phase liquid immersion coolingetc..
It is suitable for all equipment which needs heat dissipation and is installed in the open air.
fluid cooler with adiabatic system and ZIEHL-ABEGG EC fan for Immersion Cooling Solution
Immersion Cooling Solution fluid cooler Technical parameter:
Dry cooler D2 series parameter(fin space 2.1mm)
Type |
D2-148-4x630 |
D2-166-4x630 |
D2-175-4x630 |
D2-228-6x630 |
D2-250-6x630 |
D2-276-6x630 |
D2-310-8x630 |
D2-343-8x630 |
D2-364-8x630 |
D2-392-10x630 |
Capacity |
Water |
KW |
147.99 |
165.85 |
175.21 |
227.85 |
250.42 |
276.53 |
309.85 |
342.73 |
364.07 |
391.99 |
20% Et. Glycol |
KW |
142.42 |
161.57 |
170.91 |
219.09 |
244.69 |
270.22 |
301.18 |
333.55 |
354.64 |
383.3 |
Air flow |
M3/h |
76459 |
74341 |
72134 |
114686 |
111511 |
108188 |
152911 |
148675 |
144255 |
191136 |
Fan |
No. X φ |
2x2x630 |
2x2x630 |
2x2x630 |
2x3x630 |
2x3x630 |
2x3x630 |
2x4x630 |
2x4x630 |
2x4x630 |
2x5x630 |
Fan motor 400/3N/50HZ |
A |
20.4 |
20.4 |
20.4 |
30.6 |
30.6 |
30.6 |
40.8 |
40.8 |
40.8 |
51.00 |
Sound pressure level |
dB(A)10m |
64 |
64 |
64 |
66 |
66 |
66 |
67 |
67 |
67 |
68 |
Dimension |
L |
mm |
2186 |
2186 |
2186 |
3250 |
3250 |
3250 |
4250 |
4250 |
4250 |
5250 |
H |
mm |
1874 |
1874 |
1874 |
1874 |
1874 |
1874 |
1874 |
1874 |
1874 |
1874 |
D |
mm |
2100 |
2100 |
2100 |
2100 |
2100 |
2100 |
2100 |
2100 |
2100 |
2100 |
D1 |
mm |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
L1 |
mm |
963 |
963 |
963 |
963 |
963 |
963 |
963 |
963 |
963 |
963 |
L2 |
mm |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
L3 |
mm |
1963 |
1963 |
1963 |
2963 |
2963 |
2963 |
3963 |
3963 |
3963 |
4963 |
Connections inlet φ |
mm |
2XDN50 |
2XDN65 |
2XDN65 |
2XDN65 |
2XDN80 |
2XDN80 |
2XDN80 |
2XDN80 |
2XDN100 |
2XDN100 |
Connections onlet φ |
mm |
2XDN50 |
2XDN65 |
2XDN65 |
2XDN65 |
2XDN80 |
2XDN80 |
2XDN80 |
2XDN80 |
2XDN100 |
2XDN100 |
Product weight(empty) |
kg |
769 |
811 |
853 |
1134 |
1197 |
1261 |
1498 |
1589 |
1673 |
1864 |
Immersion Cooling Solution fluid cooler pictures: