• High Temperature Area Mist Spray Free Fluid Drycooler Radiator
  • High Temperature Area Mist Spray Free Fluid Drycooler Radiator
  • High Temperature Area Mist Spray Free Fluid Drycooler Radiator
  • High Temperature Area Mist Spray Free Fluid Drycooler Radiator
  • High Temperature Area Mist Spray Free Fluid Drycooler Radiator
  • High Temperature Area Mist Spray Free Fluid Drycooler Radiator

High Temperature Area Mist Spray Free Fluid Drycooler Radiator

After-sales Service: One Year
Warranty: One Year
Type: Air-Cooled
Cooling Water: Industrial Water
System Type: Closed System
Fans Species: Frequency Fan
Samples:
US$ 1000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
SLC-200
Noise Level
Ultra Low
Application Fields
Machinery
Certification
RoHS, ISO, CE
Condition
New
Air Volume
10800
Frequency(Hz)
50/60
Current(a)
0.46
Net Wieght(Kg)
500
Protection Class
IP54
Fluid
Water and Ethylene Glycol
Fan
Ziehl-Abegg
Colour
White
Transport Package
Customerized Packing
Specification
CE, UL
Trademark
Shenglin
Origin
Shanghai, China
HS Code
8418999910
Production Capacity
3000 Unit/Units / Month

Product Description

High Temperature Area Mist Spray Free Fluid Drycooler Radiator

High Temperature Area Mist Spray Free Fluid Drycooler Radiator

Products Features

1. Condensers are the first choice of refrigeraion and AC industry. Condenser with a capacity 8kW~1800kW and surface 20~4100 square meter which has wide application range. It is flexible to match which different size of compressor. Use low specific energy consumption fans, high efficiency inner groove copper tube and sine wave aluminum fin. Durable material with slim but rigid enclosure hard gloss powder coated sheet metal offers corrosion proof under hostile environment. There are top air outlet or side air outlet construct for C1 series, "V" type for C2 series. C2 float coil can prevent refrigerant leakage effictively, it ensures a durable and safety finned heat exchanger.

2. High efficiency heat exchanger: capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany

3. Fan: only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw.Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Air separator for each fan.

4. We facilitate you to have a long lasting and low maintainance operation. Durable material and rigid enclosure with hard gloss powder coated finish. Protective enclosure for both manifolds and U-bends. Unit design for outdoor installation. 100% leakage tested at 31bar.

Options
1. Coil design refrigerant: R414A, R407C

2. Multiple circuits.

3. Sub-cooling circuits.

4. Stainless steel or aluminum casing.

5. Coated aluminum, copper fins and anti-corrosion expoxy fin.

6. Explosion ploof motor.

7. Customized fin spacing.

 Condition

Air inlet temp. 25ºC; condensing temp. 40ºC; refrigerant inlot temp. 65ºC; liquid sub-cooling 3K; relative humidity 40%; atmosphere pressure 1 bar(sea level)

 Technical parameter

Air cooled condenser C2 series parameter(fin space 2.1mm)

High Temperature Area Mist Spray Free Fluid Drycooler Radiator

Paramaters:
SHSL-D1 series (fin space 2.1mm)

Type

SHSL-D1-005-1x350

SHSL-D1-006-1x350

SHSL-D1-007-1x350

SHSL-D1-009-1x450

SHSL-D1-011-1x450

SHSL-D1-013-1x450

SHSL-D1-014-1x500

SHSL-D1-017-1x500

SHSL-D1-020-1x500

Capacity

Water

35ºC outdoor temp.

Inlet

45ºC,

 

KW

4.89

5.90

6.83

9.39

10.99

13.33

14.32

17.01

19.80

outlet

40ºC

Y

20% Glycol

Inlet

45ºC

 

4.72

5.69

6.69

8.90

10.61

13.05

13.91

16.11

19.29

outlet

40ºC

Y

Medium

Water flow

M3/h

0.85

1.03

1.20

1.63

1.91

2.30

2.50

3.00

3.50

Pressure drop

kPa

36.00

31.00

58.00

25.00

40

80

50

60

40

Air flow

 

M3/h

2828

2712

2492

6199

5827

5225

8469

8168

7601

Y

Fan motor

Phase

1

1

1

3

3

3

3

3

3

 

W

140

140

140

540

540

540

830

830

830

Y

 

A

0.60

0.60

0.60

1.10

1.10

1.10

1.45

1.45

1.45

Y

Fan

No X φ

1x1x350

1x1x350

1x1x350

1x1x450

1x1x450

1x1x450

1x1x500

1x1x500

1x1x500

Sound pressure level

 

dB(A)

31

31

31

43

43

43

49

49

49

 

Y

10m

Application

Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, smelting, etc.. It is suitable for all equipment which needs heat dissipation and is installed in the open air.
High Temperature Area Mist Spray Free Fluid Drycooler RadiatorHigh Temperature Area Mist Spray Free Fluid Drycooler Radiator
Product schematic diagram
High Temperature Area Mist Spray Free Fluid Drycooler Radiator
High Temperature Area Mist Spray Free Fluid Drycooler Radiator
High Temperature Area Mist Spray Free Fluid Drycooler Radiator
High Temperature Area Mist Spray Free Fluid Drycooler Radiator
High Temperature Area Mist Spray Free Fluid Drycooler Radiator


High Temperature Area Mist Spray Free Fluid Drycooler Radiator
High Temperature Area Mist Spray Free Fluid Drycooler Radiator
 

 For further information please contact me
 Ms. Alina Shi

  
 

 
 Website: cnshenglintec.en.made-in-china.com

Send your message to this supplier

*From:
*To:
avatar Ms. Bella
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now