HVAC System Chemical Plant Dry Type Air Cooler Heat Exchanger

Product Details
Customization: Available
After-sales Service: One Year
Warranty: One Year
Still deciding? Get samples of US$ 2000/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (20)
  • HVAC System Chemical Plant Dry Type Air Cooler Heat Exchanger
  • HVAC System Chemical Plant Dry Type Air Cooler Heat Exchanger
  • HVAC System Chemical Plant Dry Type Air Cooler Heat Exchanger
  • HVAC System Chemical Plant Dry Type Air Cooler Heat Exchanger
  • HVAC System Chemical Plant Dry Type Air Cooler Heat Exchanger
  • HVAC System Chemical Plant Dry Type Air Cooler Heat Exchanger
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
SL-004
Cooling Water
Industrial Water
System Type
Closed System
Fans Species
Frequency Fan
Noise Level
Ultra Low
Application Fields
Machinery
Certification
RoHS, ISO, CE
Condition
New
Air Volume
10800
Frequency(Hz)
50/60
Current(a)
0.46
Net Wieght(Kg)
500
Protection Class
IP54
Fluid
Water and Ethylene Glycol
Fan
Ziehl-Abegg
Colour
White
Transport Package
Customerized Packing
Specification
CE, UL
Trademark
Shenglin
Origin
Shanghai, China
HS Code
8419500090
Production Capacity
30000 Unit/Units / Month

Packaging & Delivery

Package Size
5900.00cm * 2500.00cm * 1800.00cm
Package Gross Weight
500.000kg

Product Description

HVAC System Chemical Plant Dry Type Air Cooler Heat Exchanger

Product Description

Products Features

1. Condensers are the first choice of refrigeraion and AC industry. Condenser with a capacity 8kW~1800kW and surface 20~4100 square meter which has wide application range. It is flexible to match which different size of compressor. Use low specific energy consumption fans, high efficiency inner groove copper tube and sine wave aluminum fin. Durable material with slim but rigid enclosure hard gloss powder coated sheet metal offers corrosion proof under hostile environment. There are top air outlet or side air outlet construct for C1 series, "V" type for C2 series. C2 float coil can prevent refrigerant leakage effictively, it ensures a durable and safety finned heat exchanger.

2. High efficiency heat exchanger: capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany

3. Fan: only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw.Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Air separator for each fan.

4. We facilitate you to have a long lasting and low maintainance operation. Durable material and rigid enclosure with hard gloss powder coated finish. Protective enclosure for both manifolds and U-bends. Unit design for outdoor installation. 100% leakage tested at 31bar.

Air discharge direction  
Performance ranges Cooling capacity: from 5 to 649 kw
Air volume: from 2828 to 263503 m3/h
Sound pressure level: from 31 to 69 dB A(10m)
Dry coolers:customized on demand
High efficiency heat exchanger Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan.
Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition).
Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany
Fan Only choose low specific energy consumption fans.
Fan nozzle designs for maximum air flow and air throw.
Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting.
Motor: protection class IP 54 and insulation class F.
Voltage:400V/3N/50Hz
Air separator for each fan.
Testing Heat exchangers are supplied clean and tested at a pressure of 30 bars
Options Coil design refrigerant: water, oil, glycol.
Multiple circuits.
Sub-cooling circuits.
Stainless steel or aluminum casing.
Coated aluminum or copper fins.
Explosion ploof motor.
Customized fin spacing.
Hydropad.

 Technical parameter

Air cooled condenser C2 series parameter(fin space 2.1mm)

HVAC System Chemical Plant Dry Type Air Cooler Heat Exchanger

Dry cooler D2 series parameter(fin space 2.1mm)

Type D2-148-4x630 D2-166-4x630 D2-175-4x630 D2-228-6x630 D2-250-6x630 D2-276-6x630 D2-310-8x630 D2-343-8x630 D2-364-8x630 D2-392-10x630
Capacity Water KW 147.99 165.85 175.21 227.85 250.42 276.53 309.85 342.73 364.07 391.99
20% Et. Glycol KW 142.42 161.57 170.91 219.09 244.69 270.22 301.18 333.55 354.64 383.3
Air flow M3/h 76459 74341 72134 114686 111511 108188 152911 148675 144255 191136
Fan No. X φ 2x2x630 2x2x630 2x2x630 2x3x630 2x3x630 2x3x630 2x4x630 2x4x630 2x4x630 2x5x630
Fan motor
400/3N/50HZ
A 20.4 20.4 20.4 30.6 30.6 30.6 40.8 40.8 40.8 51.00
Sound pressure level dB(A)10m 64 64 64 66 66 66 67 67 67 68
Dimension L mm 2186 2186 2186 3250 3250 3250 4250 4250 4250 5250
H mm 1874 1874 1874 1874 1874 1874 1874 1874 1874 1874
D mm 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100
D1 mm 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000
L1 mm 963 963 963 963 963 963 963 963 963 963
L2 mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
L3 mm 1963 1963 1963 2963 2963 2963 3963 3963 3963 4963
Connections inlet φ mm 2XDN50 2XDN65 2XDN65 2XDN65 2XDN80 2XDN80 2XDN80 2XDN80 2XDN100 2XDN100
Connections onlet φ mm 2XDN50 2XDN65 2XDN65 2XDN65 2XDN80 2XDN80 2XDN80 2XDN80 2XDN100 2XDN100
Product weight(empty) kg 769 811 853 1134 1197 1261 1498 1589 1673 1864
Type D2-426-10x630 D2-445-12x630 D2-517-12x630 D2-525-14x630 D2-601-14x630 D2-596-16x630 D2-692-16x630 D2-676-18x630 D2-783-18x630 D2-921-20x630
Capacity Water KW 426.15 444.78 516.67 524.70 601.41 595.59 692.11 676.02 783.03 921.23
20% Et. Glycol KW 413.85 427.83 504.38 507.90 586.16 572.94 676.71 653.42 767.64 905.78
Air flow M3/h 182123 229377 218543 267604 254816 301325 290850 338987 327612 351663
Fan No. X φ 2X5X630 2X6X630 2X6X630 2X7X630 2X7X630 2X8X630 2X8X630 2X9X630 2X9X630 2X10X630
Fan motor
400/3N/50HZ
A 51.00 61.20 61.20 71.40 71.40 81.60 81.60 91.80 91.80 102.00
kW 27.50 33.00 33.00 38.50 38.50 44.00 44.00 49.50 49.50 55.00
Sound pressure level dB(A)10m 68 69 69 70 70 71 71 72 72 73
Dimension L mm 5250 6250 6250 7250 7250 8250 8250 9250 9250 10250
H mm 1874 1874 1874 1874 1874 1874 1874 1874 1874 1874
D mm 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100
D1 mm 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000
L1 mm 963 963 963 963 963 963 963 963 963 963
L2 mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
L3 mm 4963 5963 5963 6963 6963 7963 7963 8963 8963 9963
Connections inlet φ mm 2XDN100 2XDN100 2XDN100 2XDN100 2XDN125 2XDN125 2XDN125 2XDN125 2XDN125 4XDN1100
Connections onlet φ mm 2XDN100 2XDN100 2XDN100 2XDN100 2XDN125 2XDN125 2XDN125 2XDN125 2XDN125 4XDN1100
Product weight(empty) kg 2193 2224 2617 2586 3259 3244 3728 3643 4226 4283


Application

Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, smelting, etc.. It is suitable for all equipment which needs heat dissipation and is installed in the open air.

Product schematic diagram
HVAC System Chemical Plant Dry Type Air Cooler Heat ExchangerHVAC System Chemical Plant Dry Type Air Cooler Heat Exchanger
HVAC System Chemical Plant Dry Type Air Cooler Heat Exchanger
HVAC System Chemical Plant Dry Type Air Cooler Heat Exchanger
HVAC System Chemical Plant Dry Type Air Cooler Heat Exchanger

HVAC System Chemical Plant Dry Type Air Cooler Heat Exchanger
HVAC System Chemical Plant Dry Type Air Cooler Heat Exchanger
HVAC System Chemical Plant Dry Type Air Cooler Heat Exchanger
HVAC System Chemical Plant Dry Type Air Cooler Heat Exchanger

HVAC System Chemical Plant Dry Type Air Cooler Heat Exchanger
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier