• Eco Design Air to Air Counter Flow Ventilation Recuperator
  • Eco Design Air to Air Counter Flow Ventilation Recuperator
  • Eco Design Air to Air Counter Flow Ventilation Recuperator
  • Eco Design Air to Air Counter Flow Ventilation Recuperator
  • Eco Design Air to Air Counter Flow Ventilation Recuperator
  • Eco Design Air to Air Counter Flow Ventilation Recuperator

Eco Design Air to Air Counter Flow Ventilation Recuperator

After-sales Service: Online
Warranty: 1 Year
Certification: RoHS
Samples:
US$ 45/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Eco Design Air to Air Counter Flow Ventilation Recuperator pictures & photos
Eco Design Air to Air Counter Flow Ventilation Recuperator
US $1,400-1,500 / Piece
Min. Order: 10 Pieces
Manufacturer/Factory, Trading Company
Diamond Member Since 2010

Suppliers with verified business licenses

Secured Trading Service
Shanghai, China
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (19)
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
ERA-
Application
Ahu
Principle
Mixing Heat Exchanger
Style
Plate Type
Material
Stainless Steel
Model
Era, Erb, Erc, Erd
Fin Material
Aluminium, Stainless Steel
Casing Material
Aluminium, Stainless Steel
Aluminum Fin Thick
0.1-0.3mm
Era
Cross Flow Heat Exchanger Core
Erb
Counter Flow Heat Exchanger Core
Erc
Enthalpy Heat Exchanger Core
Erd
Cross&Counter Flow Heat Exchanger Core
Application 1
Air Handling Units
Application 2
Ventilation System
Application Environment
Heat Recovery/Cooling/Heating/Dehumidification
Working Principle
Use Exhaust Air to Pretreat Fresh Air
Air Channel Type
Cross/Counter/Cross&Counter Flow
Heat Exchange Type
Sensible Heat Exchanger/Total Heat Exchanger
Combination Mode
According to The Use and Installation Space
Transport Package
Wooden Packing
Specification
CE/ISO9001-2008
Trademark
Shenglin
Origin
Shanghai, China
HS Code
8415909000
Production Capacity
50 Tons Per Month

Packaging & Delivery

Package Size
85.00cm * 90.00cm * 70.00cm
Package Gross Weight
45.000kg

Product Description

Product Description

 

 Eco design air to air counter flow ventilation recuperator    

 Introduction  
      The heat exchanger core is the major part of air to air ventilation system.When the air is forced to pass through the heat exchanger core from two different air channels,the energy and humidity are transfered by the plates,so as to save the energy.
Outdoor air and exhaust air is separated by thermal conduction plate,avoid cross-contamination,make sure clean outdoor air.
Base on different air channel,they can be divided into cross flow,counter flow and cross&counter flow;base on material can be divided into sensible and enthalpy heat exchanger core.
Heat exchanger core have compact structure,no running parts,strong reliability and long service life.

ERA Cross Flow Heat Exchanger Core
      Cross flow heat exchanger core is made of antiseptic hydrophilic / epoxy coating aluminum foil and galvanized sheet cover. The air is forced to crossover through the heat exchanger core, two airstreams never come into direct contact, avoid the transfer of any smell and moisture. It is usually being used for recovering energy at residential, commercial and wind power industry ventilation systems.
Eco Design Air to Air Counter Flow Ventilation Recuperator




ERB Counter Flow Heat Exchanger Core
      Counter flow heat exchanger core is made of antiseptic hydrophilic / epoxy coating aluminum foil and galvanized sheet cover. The air is forced to counter through the heat exchanger core, two air streams never come into direct contact, avoid the transfer of any smell and moisture. It is usually being used for recovering energy at industry ventilation system, such as: base station / outdoor cabinet ventilator and so on.
Eco Design Air to Air Counter Flow Ventilation Recuperator


ERD Cross&Counter Flow Heat Exchanger Core
       Cross & counter flow heat exchanger core is made of antiseptic hydrophilic/ epoxy coating aluminum foil and galvanized sheet cover. A part of air is cross flow, and the other is counter flow,two air streams never come into direct contact, avoid the transfer of any smell and moisture. It is usually being used for recovering energy at residential household, commercial and industry ventilation systems.
Eco Design Air to Air Counter Flow Ventilation Recuperator


ERC Enthalpy Heat Exchanger Core
       Heat exchanger core is made of fireproof and antibacterial fibrous paper and ABS framework, the air is forced to crossover through the heat exchanger core, two air streams never come into direct contact, avoid the transfer of any smell and moisture. It is usually being used for residential ventilation system, in order to recover the energy and moisture.
Eco Design Air to Air Counter Flow Ventilation Recuperator


·Material of sensible heat exchanger
The sensible heat exchanger core is made of high quality hydrophilic coating aluminium foil, with fast thermal conductivity, no secondary pollution and high heat transfer rate. According to different occasion, the epoxy coating aluminium foil is able to choose from, which with higher corrosion resistance. The thickness of aluminium foil is from 0.1mm ~ 0.3mm.
·Material of total heat exchanger
The total heat exchanger core (paper core) is made of fireproof and antibacterial fibrous paper, which have high moisture permeability, good airtightness, antirends, aging resistance, anti-mildew features, the framework is made of ABS material, which is not easy to break, long service life and good impermeability. The heat exchanger core not only transfer energy but also moisture, avoid air cross-contamination, in order to achieve high efficiency.
(Types) (CO2) (NH3) (CH3) (H2O) (Fiber clearance)
(Molecular Diameter) 0.324 0.308 0.324 0.288 0.3
(Reference value)


Applications:

Applied to air handling units
The plate heat exchanger core is applied in air handling units, as the main components of heat recovery.

Applied to ventilation system
The heat exchanger core is applied in ventilation system, installed in air channel, as the main components of heat recovery, the installation position could be flexible exchange.
Eco Design Air to Air Counter Flow Ventilation Recuperator
Eco Design Air to Air Counter Flow Ventilation Recuperator
Eco Design Air to Air Counter Flow Ventilation Recuperator

Note: for further information please contact me.

Ms. Echo Lee

 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Eco Design Air to Air Counter Flow Ventilation Recuperator pictures & photos
Eco Design Air to Air Counter Flow Ventilation Recuperator
US $1,400-1,500 / Piece
Min. Order: 10 Pieces
Diamond Member Since 2010

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company
Management System Certification
ISO 9001
Export Year
2009-12-29