Basic Info.
- Work Environment
- Low-temperature Heat Pump
- Heat Source
- Air-source + Water-source
- Heating Type
- Multi-power Heat
- Application
- Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
- Certification
- CE, ISO9001, CCC, RoHS, SASO
- Installation
- Freestanding
- Storage / Tankless
- Instant / Tankless
- Housing Material
- Stainless Steel
- Use
- Green House, Hotels, Pool
- Capacity
- 7-300kw
- Heating Capacity
- 7-300kw
- Rated/Max Outlet Water Temp
- 55/60°c
- Ambient Temperature
- -35degree
- Transport Package
- Wooden Packing or Customized
- Specification
- Ctstomized
- Trademark
- Shanghai Shenglin
- Origin
- Shanghai, China(Mainland)
- HS Code
- 8418612090
- Production Capacity
- 30000units/Month
Product Description

Commercial water heater heat pump series
| MODEL | KFXR-010UI | KFXR-018UII | KFXR-023UII | KFXR-036UII | KFXR-045UII | KFXR-070UII | KFXR-090UII | |
| Heating mode | Circulating | |||||||
| Ambient temp. range | ºC | -15~+43ºC | ||||||
| Rated heating capacity | KW | 10 | 18 | 23 | 36 | 45 | 70 | 90 |
| COP | W/W | 4.17 | 4.3 | 4 | 4.2 | 4.2 | 4.1 | 4.1 |
| Rated power input | KW | 2.4 | 4.2 | 5.75 | 8.57 | 10.7 | 17 | 21.9 |
| Max. running current | A | 17 | 14 | 16 | 24.8 | 30 | 45 | 58 |
| Power supply | / | 220V 1N~50Hz | 380v 3N~50Hz | |||||
| IP code | / | IPX4 | ||||||
| Safety function | / | High and low pressure protection, Overload protection, Temperature protection Power phase sequence protection, etc. | ||||||
| Refrigerant type/weight | -/kg | R407c/1.4 | R407c/2.7 | R407c/2.5 | R407c/2.0*2 | R407c/2.5*2 | R407c/7.5*2 | R407c/8.5*2 |
| Compressor QTY | PCS | 1 | 1 | 1 | 2 | 2 | 2 | 2 |
| Compressor type | / | Scroll | ||||||
| Max. temp. outlet water | ºC | 60 | ||||||
| Water side heat exchanger type | / | Casing/high efficiency tank | High efficiency tank | Casing | High efficiency tank | |||
| Air side heat exchanger type | / | Finned heat exchanger | ||||||
| Circulating waterpipe nozzle | inch | G3/4'' Internal thread | G1'' Internal thread | G1.2'' Internal thread | G1.5'' Internal thread | G1.5'' Internal thread | DN100 | DN100 |
| Outlet nozzle | inch | G3/4'' Internal thread | G1'' Internal thread | G1.2'' Internal thread | G1.5'' Internal thread | G1.5'' Internal thread | DN100 | DN100 |
| Circulating water flow | inch | 1.72 | 3.1 | 3.95 | 6.2 | 7.74 | 12.04 | 15.48 |
| Air out type | / | Top discharge | ||||||
| Fan motor QTY | PCS | 1 | 1 | 1 | 2 | 2 | 2 | 2 |
| Noise | dB/(A) | 56 | 56 | 57 | 59 | 65 | 69 | 72 |
| Machine dimension (W×D×H) | mm | 750×690×870 | 750×690×1070 | 830×793×1084 | 1500×690×1070 | 1500×690×1270 | 2100×1100×2000 | 2100×1100×2000 |
| Packing dimension (W×D×H) | mm | 800×740×1000 | 800×740×1200 | 900×930×1200 | 1550×740×1200 | 1550×740×1400 | 2140×1200×2040 | 2140×1200×2040 |
| Net weight | kg | 110 | 130 | 150 | 290 | 350 | 700 | 800 |
| Gross weight | kg | 130 | 150 | 170 | 330 | 390 | 750 | 860 |
1. Test conditions: (DB/WB) 20°C/15°C, inlet water temperature 15°C, outlet water temperature 55°C.
2. Due to product improvement, above datas are subject to change without prior notice, please take the rating plate as standard.
Geothermal water to water heat pump series
| Model | SFXKR-017II | SFXKR-032II | SFXK-015II | SFXK-040II | |||
| Ambient temp. range | ºC | -5~+25 | -5~+25 | -5~+25 | -5~+25 | ||
| Power Supply | / | 380V 3N~50Hz | |||||
| Electric shock proof grade | / | Class I | Class I | Class I | Class I | ||
| Protection grade | / | IPX4 | IPX4 | IPX4 | IPX4 | ||
| Floor heating capacity/COP | KW/- | 17/4.8 | 32/4.8 | 15/4.8 | 40/4.8 | ||
| Rated heating capacity/COP | KW/- | 16/4.1 | 31/4.1 | 13.7/4.1 | 36.5/4.1 | ||
| Rated cooling capacity/COP | KW/- | 15/5 | 28.5/5 | 13.0/5 | 34/5 | ||
| Domestic Water heating capacity/COP | KW/- | 16.5/4.4 | 28.5/4.4 | / | / | ||
| Floor heating input power. | KW | 3.5 | 6.7 | 3.13 | 8.3 | ||
| Rated heating input power | KW | 3.9 | 7.6 | 3.74 | 8.9 | ||
| Rated cooling input power | KW | 3 | 5.7 | 2.6 | 6.8 | ||
| Domestic water heating power | KW | 3.8 | 6.5 | / | / | ||
| Max. working current | A | 11.8 | 23 | 10 | 28 | ||
| Refrigerant/weight | -/kg | R410a/2.5 | R410a/2.5×2 | R410a/2.5 | R410a/4.0×2 | ||
| Compressor | Type | / | Scroll | Scroll | Scroll | Scroll | |
| Quantity | PCS | 1 | 2 | 1 | 2 | ||
| Water yield | L/h | 1400 | 2600 | 1200 | 3200 | ||
| Dimension (W×D×H) | mm | 745×650×960 | 1400×750×960 | 745×650×960 | 1400×750×960 | ||
| Packing dimension(W×D×H) | mm | 805×700×1020 | 1460×810×1020 | 805×700×1020 | 1460×810×1020 | ||
| Heat exchanger | Heat source side | Type | / | Plate heat exchanger or Tube in shell heat exchanger | |||
| Max/low outlet temperature | ºC | +25~-5 (Antifreeze solution with 25% ethylene glycol) | |||||
| Water inlet size | inch | G1''A internal thread | G1 1/2'' internal thread | G1 internal thread | DN40 | ||
| Water flow volume | m³/h | 1.4 | 2.6 | 1.2 | 3.2 | ||
| Water pressure loss(Max.) | kPa | ≤25 | ≤30 | ≤30 | ≤30 | ||
| Use side | Type | / | plate heat exchanger or Tube in shell heat exchanger | ||||
| Maximum/low outlet temperature | ºC | 58/5 | 58/5 | 58/5 | 58/5 | ||
| Nozzle size | inch | G1''A internal thread | G1 1/2'' internal thread | G1 | DN40 | ||
Domestic water side |
Type | / | High-efficiency tank heat exchanger | ||||
| Maximum/low outlet temperature | ºC | 60 | 60 | 60 | 60 | ||
| Rate Flow | m³/h | 2.84 | 4.9 | 2.4 | 6.5 | ||
| Nozzle size | inch | G1'' internal thread | G1 1/2'' internal thread | G1'' internal thread | G1 1/2'' internal thread | ||
b: Rated heating condition:Heat source side inlet temperature 0 ºC and use side inlet water temperature 30ºC;
c: Rated cooling condition:Heat source side inletwater temperature is 25ºC and outlet water temperature is 30ºC; use side inlet water temperature is 12ºC and outlet water temperature is 7ºC.
*Due to product improvement, above datas are subject to change without prior notice, please take the nameplate as standard.
Product Testing





Send your message to this supplier
People who viewed this also viewed
Product Groups
More
Find Similar Products By Category
- Supplier Homepage
- Products
- Chiller and heat pump
- Heat Pump
- Stainless Steel Explosion-Proof Air Source Water Heater Heat Pump
Related Categories
Hot Searches
More