• Heat Pump Type Air Conditioner Unit
  • Heat Pump Type Air Conditioner Unit
  • Heat Pump Type Air Conditioner Unit
  • Heat Pump Type Air Conditioner Unit
  • Heat Pump Type Air Conditioner Unit

Heat Pump Type Air Conditioner Unit

Type: Heat Pump Air Conditioner
Capacity: 18000-24000 BTU
Usage: Room, Car, Commerical...
Indoor Machine Noise: 36-49dB
Certification: CE, RoHS, UL
China Energy Efficiency Standard: Level 1
Customization:
Manufacturer/Factory, Trading Company
Diamond Member Since 2010

Suppliers with verified business licenses

Shanghai, China
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (19)

Basic Info.

Model NO.
SLG100D
Cooling/Heating
Cooling/Heating
Power Source
Electrical
Power Type
DC
Condition
New
Product Name
Heat Pump Type Air Conditioner Unit
Air Condition Sider
Plate Heat Exchanger
Water Tank Side
Double Pipe Heat Exchanger
Source Side Heat Exchanger
Plate Heat Exchanger
Outlet Water Max Temp (°c)
55
Defend Grade
Ipx4
Body
Spray Coating Metal Plate
Refrigerant
Spray Coating Metal Plate
Heating Capacity
80kw
Transport Package
Wooden Packing
Specification
ROHS
Trademark
Shenglin
Origin
Shanghai, Ningbo
HS Code
85864312
Production Capacity
10000 Units/Month

Product Description

Heat Pump Type Air Conditioner Unit

We are a heat pump manufactures! The Advantages as the following
1) Generally cost less to operate than other types of conventional heating systems, save your electricity or gas bills.
2) Operate at a high efficiency with no flames, fumes, or flues; Water and electricity isolated
3) Transfer heat that's already in the environment; Low CO2 emissions.
4) With intelligent control systems which convenient and simple operation
5) Provide hot water no matter in cloudy day, snowy day or at night, unlike solar collectors which have to be facing the sun.
6) Wide application
7) It can be applied to sanitary hot water, house heating and so on.


Excellent quality water cold evi heat pump
Product Description:
1. Five modes:
Hot water, Heating, Cooling, Heating Hot water, Cooling Hot water.
2. LCD display wire controller.
3. Heating and cooling control combined with room temperature controller.
4. Control solar collector working(one phase units).
5. Freely set opening cycle time in advance.
6. Unit runs automatically according to set water temperature or indoor temp...
7. Can control the auxiliary heating (e. G. Electric heating).
8. With hot water supply control(three phase units).
9. With water return control, to avoid waste of cold water or waiting.
10. Water Level Display and can be adjusted freely(three phase units).
11. Flow switch for water flow protection.
12. Heat-exchanger cycle technology to improve low temperature operation.
13. Automatic prevent freezing in the winter.
14. Automatic defrosting.
15. Use the high-temperature compressor(T3 condition).
16. Expansion valve regulates flow of refrigerant precisely.
17. Air exchanger(Fins-coil) with hydrophilic coating.
18. Water side equired with tube in tube exchanger or EST high efficiency exchanger.
19. Modular design, free combination(three phase units).
 
Model SLA30D SLA50D SLA100D SLA200D
input power          kw 2.98 4.6 9.2 19
heating capacity   kw 12 18.4 63.8 72
cooling capacity   kw 8.8 13 27 56
Current                 A 13/6 9 18 35
Power supply       V 220/380 380
Hot Water supply L/H 280 400 800 1600
Water flow           L/H 3600 5500 11000 22000
Pipe size DN25 DN25 DN32 DN50
Refrigerant R417A/R404A/R407C/R410A/R134A
Noise                    Db ≤50 ≤55 ≤70 ≤75
Compressor   Copeland          
Weight                  Kg 120 165 320 640
Dimension            mm 1120*490*790 1120*490*1260 1450*760*1060 1990*980*2080
Packing dimension mm 1200*520*870 1200*520*1440 1520*800*1230 2060*1060*2230
Condenser:Double-pipe heat exchanger, Evaporator:Finned heat exchanger, Throttle unit:Electronic expansion valve. BodySpray coating.
Test condition: Dry bulb 20ºC,Wet bulb 15ºC, Input water temp 15ºC, Output 55ºC

Specifications:
Refrigerant
R417A/R407C/R404A/R410A/R22/R134A
Compressor
 
Copeland
Condenser: Double-pipe heat exchanger.
Evaporator: Plate heat exchanger. The heat source is the water.
Throttle unit: Electronic expansion valve / Thermal expansion valve/ Capillary
Body: Spray coating metal plate (Stainless steel body should add price)


Advantages:
1) Generally cost less to operate than other types of conventional heating systems, save your electricity or gas bills.
2) Operate at a high efficiency with no flames, fumes, or flues; Water and electricity isolated
3) Transfer heat that's already in the environment; Low CO2 emissions.
4) With intelligent control systems which convenient and simple operation
5) Provide hot water no matter in cloudy day, snowy day or at night, unlike solar collectors which have to be facing the sun.
6) It can be applied to sanitary hot water, house heating and so on.Heat Pump Type Air Conditioner UnitHeat Pump Type Air Conditioner UnitHeat Pump Type Air Conditioner UnitHeat Pump Type Air Conditioner Unit
Heat Pump Type Air Conditioner Unit

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now