Heat Exchange Dry Type Air Cooler for Computer Data Center
Cooling capacity range:5kw to 649kw
Air volume: from 2828 to 263503 m3/h
Sound pressure level: from 31 to 69 dB A(10m)
Dry coolers:customized on demand
High efficiency heat exchanger
Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan.
Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition).
Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany
Fan
Only choose low specific energy consumption fans.
Fan nozzle designs for maximum air flow and air throw.
Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting.
Motor: protection class IP 54 and insulation class F.
Voltage:400V/3N/50Hz
Air separator for each fan.
Heat exchangers are supplied clean and tested at a pressure 30bars
Features
Air discharge direction |
|
Performance ranges |
Cooling capacity: from 5 to 649 kw |
High efficiency heat exchanger |
Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. |
Fan |
Only choose low specific energy consumption fans. |
Testing |
Heat exchangers are supplied clean and tested at a pressure of 30 bars |
Options |
Coil design refrigerant: water, oil, glycol. |
Type |
SHSL-D1-005-1x350 |
SHSL-D1-006-1x350 |
SHSL-D1-007-1x350 |
SHSL-D1-009-1x450 |
SHSL-D1-011-1x450 |
SHSL-D1-013-1x450 |
SHSL-D1-014-1x500 |
SHSL-D1-017-1x500 |
SHSL-D1-020-1x500 |
||||||
Capacity |
Water |
35ºC outdoor temp. |
Inlet |
45ºC, |
△ |
KW |
4.89 |
5.90 |
6.83 |
9.39 |
10.99 |
13.33 |
14.32 |
17.01 |
19.80 |
outlet |
40ºC |
Y |
|||||||||||||
20% Glycol |
Inlet |
45ºC |
△ |
4.72 |
5.69 |
6.69 |
8.90 |
10.61 |
13.05 |
13.91 |
16.11 |
19.29 |
|||
outlet |
40ºC |
Y |
|||||||||||||
Medium |
Water flow |
M3/h |
0.85 |
1.03 |
1.20 |
1.63 |
1.91 |
2.30 |
2.50 |
3.00 |
3.50 |
||||
Pressure drop |
kPa |
36.00 |
31.00 |
58.00 |
25.00 |
40 |
80 |
50 |
60 |
40 |
|||||
Air flow |
△ |
M3/h |
2828 |
2712 |
2492 |
6199 |
5827 |
5225 |
8469 |
8168 |
7601 |
||||
Y |
|||||||||||||||
Fan motor |
Phase |
1 |
1 |
1 |
3 |
3 |
3 |
3 |
3 |
3 |
|||||
△ |
W |
140 |
140 |
140 |
540 |
540 |
540 |
830 |
830 |
830 |
|||||
Y |
|||||||||||||||
△ |
A |
0.60 |
0.60 |
0.60 |
1.10 |
1.10 |
1.10 |
1.45 |
1.45 |
1.45 |
|||||
Y |
|||||||||||||||
Fan |
No X φ |
1x1x350 |
1x1x350 |
1x1x350 |
1x1x450 |
1x1x450 |
1x1x450 |
1x1x500 |
1x1x500 |
1x1x500 |
|||||
Sound pressure level |
△ |
dB(A) |
31 |
31 |
31 |
43 |
43 |
43 |
49 |
49 |
49 |
||||
Y |
10m |
||||||||||||||
Dimension |
L |
mm |
870 |
870 |
870 |
1020 |
1020 |
1020 |
1220 |
1220 |
1220 |
||||
W |
mm |
525 |
525 |
525 |
625 |
625 |
625 |
825 |
825 |
825 |
|||||
H |
mm |
797 |
797 |
797 |
820 |
820 |
820 |
870 |
870 |
870 |
|||||
A |
mm |
690 |
690 |
690 |
840 |
840 |
840 |
1040 |
1040 |
1040 |
|||||
B |
mm |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
|||||
C |
mm |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
|||||
D |
mm |
490 |
490 |
490 |
490 |
490 |
490 |
490 |
490 |
490 |
|||||
Inlet φ |
mm |
3/4" |
3/4" |
3/4" |
1" |
1" |
1" |
1-1/4" |
1-1/4" |
1-1/4" |
|||||
Inlet φ |
mm |
3/4" |
3/4" |
3/4" |
1" |
1" |
1" |
1-1/4" |
1-1/4" |
1-1/4" |
|||||
Product weight(empty) |
kg |
38 |
42 |
48 |
55 |
60 |
67 |
75 |
82 |
91 |