• Dry Cooling Tower Adiabatic Dry Cooler for Liquid Immersion Cooling
  • Dry Cooling Tower Adiabatic Dry Cooler for Liquid Immersion Cooling
  • Dry Cooling Tower Adiabatic Dry Cooler for Liquid Immersion Cooling
  • Dry Cooling Tower Adiabatic Dry Cooler for Liquid Immersion Cooling
  • Dry Cooling Tower Adiabatic Dry Cooler for Liquid Immersion Cooling
  • Dry Cooling Tower Adiabatic Dry Cooler for Liquid Immersion Cooling

Dry Cooling Tower Adiabatic Dry Cooler for Liquid Immersion Cooling

After-sales Service: Online Technical Support
Warranty: 1 Year
Type: Air-Cooled
Cooling Water: Industrial Water
System Type: Closed System
Fans Species: Frequency Fan
Samples:
US$ 5168/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory, Trading Company
Diamond Member Since 2010

Suppliers with verified business licenses

Shanghai, China
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (19)

Basic Info.

Model NO.
SHSL5168
Noise Level
Low
Application Fields
Liquid Immersion Cooling Dry Cooler
Certification
RoHS, ISO, CE
Condition
New
Product Name
Liquid Immersion Cooling Dry Cooler
Tube Material
Copper, Aluminium, Steel, Stainless Steel
Fin Material
Copper, Aluminium, Steel, Stainless Steel
Fan
Ziehl-Abegg Fan, Emb
Tube O.D.
12.75, 15.88mm
Fin Thickness
0.15mm
Advantage 1
Epoxy Coating
Advantage 2
SS316L
Advantage 3
Adiabatic Coolers
Advantage 4
with Spray
Advantage 5
Frequency Control
Advantage 6
Advanced Design Software
Transport Package
Customerized Packing
Specification
SGS
Trademark
Shenglin
Origin
Shanghai, China(Mainland)
HS Code
8415909000
Production Capacity
1000 Unit/Month

Product Description

High Heat Exchange Efficiency Dry Cooling Tower Adiabatic Dry Cooler for liquid immersion cooling with Ziehl-Abegg fan 

Dry coolers are available in a wide performance range between approx. 5 and 2,000 kW dry cooling performance. Depending on case of application, you can select between different series. All dry coolers are available in different noise levels and naturally suitable for outside installation. Water or water-glycol mixtures can be used as cooling medium. 

In case you do not find the type or model in the website, we can customized according to your request. please contact me
Dry Cooling Tower Adiabatic Dry Cooler for Liquid Immersion Cooling

success case for dry cooler 
Dry Cooling Tower Adiabatic Dry Cooler for Liquid Immersion Cooling

 

Air discharge direction

 

Performance ranges

Cooling capacity: from 5 to 649 kw
Air volume: from 2828 to 263503 m3/h
Sound pressure level: from 31 to 69 dB A(10m)
Dry coolers:customized on demand

High efficiency heat exchanger

Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan.
Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition).
Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany

Fan

Only choose low specific energy consumption fans.
Fan nozzle designs for maximum air flow and air throw.
Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting.
Motor: protection class IP 54 and insulation class F.
Voltage:400V/3N/50Hz
Air separator for each fan.

Testing

Heat exchangers are supplied clean and tested at a pressure of 30 bars

Options

Coil design refrigerant: water, oil, glycol.
Multiple circuits.
Sub-cooling circuits.
Stainless steel or aluminum casing.
Coated aluminum or copper fins.
Explosion ploof motor.
Customized fin spacing.
Hydropad.

Optional features:
EC variable speed fan motor, to save great energy
ZAplus/AxiTop for greater volume flow and extreme silence
Adiabatic system significantly reduce energy consumption in summer
Epoxy coated or hydrophilic aluminum fin suitable for coastal or high corrosion area
Fluid dry cooler
Clean stainless steel tube and aluminum fin coil for cooling deionized water.
Product showing 



liquid immersion cooling Air Cooled Dry Cooler Features
Unique floating coil design avoids leakage caused by thermal expansion and contraction.
Staggered fin pattern design and corrugated fin enhance air flow turbulence
Inner-grooved copper tube increase heat transfer area and enhance heat transfer
Optimized flow pass design ensure fully heat exchange with refrigerant
Equipped with 2nd generation owl-wing fan motor as standard. It features with low noise level, large volume flow and low energy consumption. Ready for dual speed connection.
Outdoor type powder coated casing made of galvanized sheet metal and stainless steel bolts provide a high resistance to corrosion.


liquid immersion cooling Dry cooler SHSL-D1 series parameter(fin space 2.1mm)

Type

SHSL-D1-005-1x350

SHSL-D1-006-1x350

SHSL-D1-007-1x350

SHSL-D1-009-1x450

SHSL-D1-011-1x450

SHSL-D1-013-1x450

SHSL-D1-014-1x500

SHSL-D1-017-1x500

SHSL-D1-020-1x500

Capacity

Water

35ºC outdoor temp.

Inlet

45ºC,

KW

4.89

5.90

6.83

9.39

10.99

13.33

14.32

17.01

19.80

outlet

40ºC

Y

20% Glycol

Inlet

45ºC

4.72

5.69

6.69

8.90

10.61

13.05

13.91

16.11

19.29

outlet

40ºC

Y

Medium

Water flow

M3/h

0.85

1.03

1.20

1.63

1.91

2.30

2.50

3.00

3.50

Pressure drop

kPa

36.00

31.00

58.00

25.00

40

80

50

60

40

Air flow

M3/h

2828

2712

2492

6199

5827

5225

8469

8168

7601

Y

Fan motor

Phase

1

1

1

3

3

3

3

3

3

W

140

140

140

540

540

540

830

830

830

Y

A

0.60

0.60

0.60

1.10

1.10

1.10

1.45

1.45

1.45

Y

Fan

No X φ

1x1x350

1x1x350

1x1x350

1x1x450

1x1x450

1x1x450

1x1x500

1x1x500

1x1x500

Sound pressure level

dB(A)

31

31

31

43

43

43

49

49

49

Y

10m

Dimension

L

mm

870

870

870

1020

1020

1020

1220

1220

1220

W

mm

525

525

525

625

625

625

825

825

825

H

mm

797

797

797

820

820

820

870

870

870

A

mm

690

690

690

840

840

840

1040

1040

1040

B

mm

--

--

--

--

--

--

--

--

--

C

mm

--

--

--

--

--

--

--

--

--

D

mm

490

490

490

490

490

490

490

490

490

Inlet φ

mm

3/4"

3/4"

3/4"

1"

1"

1"

1-1/4"

1-1/4"

1-1/4"

Inlet φ

mm

3/4"

3/4"

3/4"

1"

1"

1"

1-1/4"

1-1/4"

1-1/4"

Product weight(empty)

kg

38

42

48

55

60

67

75

82

91


liquid immersion cooling refer pictures

Dry Cooling Tower Adiabatic Dry Cooler for Liquid Immersion CoolingDry Cooling Tower Adiabatic Dry Cooler for Liquid Immersion CoolingDry Cooling Tower Adiabatic Dry Cooler for Liquid Immersion Cooling


What is free cooling system?

Dry cooler and chiller can work together as free cooling system, If you want to know more, please contact me:
Dry Cooling Tower Adiabatic Dry Cooler for Liquid Immersion Cooling
During cool weather the free cooler or watersize economizer is capable of handling the entire cooling load. 
 
During warm weather, when the free coolers cannot cool as efficiently they cannot keep up with the cooling requirements so the system automatically switches the chiller system on to provide supplemental cooling. 
 
This system provides a number of benefits:
 
The primary benefit is the energy savings.  Turning off the compressor saves a huge amount of energy.  Typically, running a free cooler can reduce your energy consumption by more than 75%. 
 
Second this system guarantees a long operating life because most of the year the load is taken off the chiller and specifically the compressor. This significantly reduces the compressors yearly running hours and provides a longer system life span.


Closed loop cooling system 
Dry cooler can instead cooling tower to offer cold water to water cooled chiller, If you want to know more, please contact me
Dry Cooling Tower Adiabatic Dry Cooler for Liquid Immersion Cooling
1. Cooling tower added chemicals, and chemicals are not good to environment. However, dry cooler only use water or glycol water, no chemicals.

2. Cooling tower system is not closed loop cooling system, However, dry cooler system is closed loop cooling system, this will save water resource.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now