Dry Air Cooler for Immersion Cooling Mobile Datacenters

Product Details
Customization: Available
After-sales Service: Online Services
Warranty: 1year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (20)
  • Dry Air Cooler for Immersion Cooling Mobile Datacenters
  • Dry Air Cooler for Immersion Cooling Mobile Datacenters
  • Dry Air Cooler for Immersion Cooling Mobile Datacenters
  • Dry Air Cooler for Immersion Cooling Mobile Datacenters
  • Dry Air Cooler for Immersion Cooling Mobile Datacenters
  • Dry Air Cooler for Immersion Cooling Mobile Datacenters
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
SHSL-D2-150-8X630F2
Type
Air-Cooled
Cooling Water
Industrial Water
System Type
Open System
Fans Species
Frequency Fan
Noise Level
Ultra Low
Application Fields
Machinery
Certification
RoHS, CE
Condition
New
Frame Material
Copper, Alminum, Stainless Steel
Tube Material
Copper, Aluminum, Stainless Steel
Cooling Capacity Range
5~649kw
HS
8418692090, 8415812090, 8418612090
Company Capacity 1
Has Ability to Offer Selection and Calculation Se
Company Capacity 2
Management Team Staff More Than 15 Years Experienc
Material
Cu Tube,Ai Fin
Fan Brand
Weiguang,Kemao,Ziehl,Ebm
Cooling Medium
Dielectric Fluid,Bc-888,S5X
Application
Data Center/Power Plant/Bitcoin Farm
Power
220V/380V/415V/440V
Fan Type
Axial Flow Fan
Brand
Shenglin
Tube Diameter
9.52/15.88mm
Fan Noise
64dB(a)10m
Transport Package
Customized
Specification
CE, ROHS
Trademark
Shanghai Shenglin
Origin
China(Mainland)
HS Code
8418699090
Production Capacity
315 Units/Month

Packaging & Delivery

Package Size
3500.00cm * 1250.00cm * 600.00cm
Package Gross Weight
1200.000kg

Product Description

Product Description

 

Industrial Dry Free Cooler for immersion mining

 Our company
Shanghai Shenglin is a professional manufacturer in China specializes in refrigeration units ,dry coolers and air conditioning units.
 

Dry coolers are mainly for machine cooling, process cooling, oil cooling, free cooling and cold room cooling.

Our products have been exported to Europe, North of America, Middle East, South of Africa and Southeast Asia more than 16 years.

We sincerely welcome customers all over the world to visit our company and set up business relationship for mutual benefit.
 
Immersion cooling involves submerging Bitcoin miners in a non-conductive fluid. Though counterintuitive to submerge in a clear, dielectric fluid - fluid is much more effective at dissipating heat than air (roughly 1600x more effective).
 
Many large data centers have already moved or are seriously considering the move to immersion cooling
 
The most cost-effective way to remove heat and a necessary component of the immersion cooling system. We designed a full portfolio of immersion optimized dry coolers. From 5kW signle fan unit to the V-shaped 48-921kW dry coolers. Made in China, sized to your needs.
Dry Air Cooler for Immersion Cooling Mobile Datacenters

Industrial Air conditioner Dry Air Cooler for Cooling Machine  

Cooling capacity range:5kw to 649kw

 Air volume: from 2828 to 263503 m3/h
Sound pressure level: from 31 to 69 dB A(10m)
Dry coolers:customized on demand
High efficiency heat exchanger
Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan.
Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition).
Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany
Fan
Only choose low specific energy consumption fans.
Fan nozzle designs for maximum air flow and air throw.
Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting.
Motor: protection class IP 54 and insulation class F.
Voltage:400V/3N/50Hz
Air separator for each fan.

Heat exchangers are supplied clean and tested at a pressure 30bars

Features

 

Air discharge direction

Dry Air Cooler for Immersion Cooling Mobile Datacenters

Performance ranges

Cooling capacity: from 5 to 649 kw
Air volume: from 2828 to 263503 m3/h
Sound pressure level: from 31 to 69 dB A(10m)
Fluid coolers:customized on demand

High efficiency heat exchanger

Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan.
Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition).
Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany

Fan

Only choose low specific energy consumption fans.
Fan nozzle designs for maximum air flow and air throw.
Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting.
Motor: protection class IP 54 and insulation class F.
Voltage:400V/3N/50Hz
Air separator for each fan.

Testing

Heat exchangers are supplied clean and tested at a pressure of 30 bars

Options

Coil design refrigerant: water, oil, glycol.
Multiple circuits.
Sub-cooling circuits.
Stainless steel or aluminum casing.
Coated aluminum or copper fins.
Explosion ploof motor.
Customized fin spacing.


Technical Data

Fluid cooler SHSL-D1 series parameter(fin space 2.1mm)

Type

SHSL-D1-005-1x350

SHSL-D1-006-1x350

SHSL-D1-007-1x350

SHSL-D1-009-1x450

SHSL-D1-011-1x450

SHSL-D1-013-1x450

SHSL-D1-014-1x500

SHSL-D1-017-1x500

SHSL-D1-020-1x500

Capacity

Water

35ºC outdoor temp.

Inlet

45ºC,

KW

4.89

5.90

6.83

9.39

10.99

13.33

14.32

17.01

19.80

outlet

40ºC

Y

20% Glycol

Inlet

45ºC

4.72

5.69

6.69

8.90

10.61

13.05

13.91

16.11

19.29

outlet

40ºC

Y

Medium

Water flow

M3/h

0.85

1.03

1.20

1.63

1.91

2.30

2.50

3.00

3.50

Pressure drop

kPa

36.00

31.00

58.00

25.00

40

80

50

60

40

Air flow

M3/h

2828

2712

2492

6199

5827

5225

8469

8168

7601

Y

Fan motor

Phase

1

1

1

3

3

3

3

3

3

W

140

140

140

540

540

540

830

830

830

Y

A

0.60

0.60

0.60

1.10

1.10

1.10

1.45

1.45

1.45

Y

Fan

No X φ

1x1x350

1x1x350

1x1x350

1x1x450

1x1x450

1x1x450

1x1x500

1x1x500

1x1x500

Sound pressure level

dB(A)

31

31

31

43

43

43

49

49

49

Y

10m

Dimension

L

mm

870

870

870

1020

1020

1020

1220

1220

1220

W

mm

525

525

525

625

625

625

825

825

825

H

mm

797

797

797

820

820

820

870

870

870

A

mm

690

690

690

840

840

840

1040

1040

1040

B

mm

--

--

--

--

--

--

--

--

--

C

mm

--

--

--

--

--

--

--

--

--

D

mm

490

490

490

490

490

490

490

490

490

Inlet φ

mm

3/4"

3/4"

3/4"

1"

1"

1"

1-1/4"

1-1/4"

1-1/4"

Inlet φ

mm

3/4"

3/4"

3/4"

1"

1"

1"

1-1/4"

1-1/4"

1-1/4"

Product weight(empty)

kg

38

42

48

55

60

67

75

82

91


Note: Standard SHSL-D1 remote radiator is vertical air discharge, for horizontal air discharge please add "H" in nomenclature, for excmple:SHSL-D1-005H-1X350
  • Reference
    Dry Air Cooler for Immersion Cooling Mobile Datacenters
    Dry Air Cooler for Immersion Cooling Mobile Datacenters
Dry Air Cooler for Immersion Cooling Mobile Datacenters
Dry Air Cooler for Immersion Cooling Mobile Datacenters
Dry Air Cooler for Immersion Cooling Mobile DatacentersDry Air Cooler for Immersion Cooling Mobile Datacenters
Dry Air Cooler for Immersion Cooling Mobile Datacenters


FAQ

Q1. Are you manufacturer or Trade Company?

We are manufacture factory and we can accept OEM order.

Q2. What's the order process?

1) Inquiry---provide us all clear requirements.

2) Quotation---official quotation list with all clear specifications.

3) PI--Confirm all the order technical data and price

4) Payment terms--- T/T deposit in advance

5) Production---mass production

6) Shipping--- by sea. Detailed picture of package will be provided.

7) After-sales Service--Any questions, we will try best to assist to solve for you.

Q3. How to get a prompt quotation?

When you send the inquiry to us, pls kindly send it with below technical information.

A. Function: Cooling only or cooling and heating?

B. Capacity: _____KW or ___Ton

C. Refrigerant: R407C, R410a or R134a

D. Voltages and Frequency : ______V/PH/HZ

E.Application:
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier