415V Heat Recovery Wheel Rooftop Air Conditioner Unit for medical clinics
Rooftop Air Conditioner parameter
Model |
WRF12ZA |
WRF 15ZA |
WRF18ZA |
WRF24ZA |
WRF30ZA |
WRF 35ZA |
WF12ZA |
WF 15ZA |
WF18ZA |
WF24ZA |
WF30ZA |
WF 35ZA |
Cooling capacity |
kW |
12 |
15.2 |
17.5 |
24 |
30.3 |
35.6 |
Heating capacity |
kW |
13.2 |
16.6 |
18.4 |
26.5 |
33.3 |
37.7 |
Energy regulation
|
% |
0,100% |
0,50,100% |
Power |
380V / 3Ph / 50HZA |
Cooling input capacity |
kW |
4.1 |
5.3 |
5.5 |
8.8 |
11.3 |
12.3 |
Heating input capacity |
kW |
3.8 |
4.8 |
5.1 |
8.2 |
10.4 |
11.3 |
Start current |
A |
48 |
62 |
63 |
63 |
74 |
76 |
Cooling running current |
A |
7.4 |
9.7 |
10.2 |
16.1 |
21.2 |
23.3 |
Heating running current |
A |
6.9 |
9.2 |
9.7 |
15.1 |
20.1 |
22.2 |
Throttling method
|
Thermal expansion valve
|
Cooling system |
1 |
1 |
1 |
1 |
2 |
2 |
Refrigerant |
R410A |
Compressor |
Compressor type |
Hermetic scroll compressor
|
Qty |
1 |
1 |
1 |
1 |
2 |
2 |
Condensation side
|
|
Condenser |
Type |
Copper tube and aluminum fin |
Qty |
1 |
1 |
1 |
1 |
1 |
1 |
Drive type |
Direct drive |
Motor power |
kW |
0.25 |
0.37 |
0.37 |
0.55 |
0.75 |
0.75 |
Air volume |
m3 /h |
4600 |
7800 |
7800 |
9000 |
12600 |
12600 |
Evaporation side
|
|
Evapotator |
Type |
Copper tube and aluminum fin |
Qty |
1 |
1 |
1 |
1 |
1 |
1 |
Motor power |
kW |
0.32 |
0.37 |
0.45 |
1.1 |
1.5 |
2.2 |
Air volume |
m3 /h |
2100 |
2600 |
3400 |
4100 |
5200 |
6300 |
Drive type |
Direct drive |
Pulley |
Static pressure(Pa) |
100 |
100 |
100 |
200 |
200 |
250 |
Filter |
Aluminum filter G3 |
Noise dB(A) |
67 |
67 |
68 |
71 |
72 |
72 |
Refrigerant filling volume(kg) |
3.1 |
3.1 |
4.3 |
2x3.1 |
2x3.1 |
2x4.3 |
External dimension |
L |
mm |
1410 |
1410 |
1410 |
1978 |
1978 |
1978 |
W |
mm |
1100 |
1100 |
1100 |
1175 |
1175 |
1175 |
H |
mm |
1095 |
1095 |
1095 |
1095 |
1095 |
1095 |
Weight |
kg |
240 |
260 |
290 |
420 |
480 |
500 |
Rooftop Air Conditioner feature:
1, Complying with above China Standard, which is from ARI standard. ISO9001 and ISO14001 qualified.
2, Choose best materials, main components are from China top brand or imported.
3, The modular casing design, easy interchanging each other. easy install,easy transport,easy maintaince.
4, Unique no-cold-bridge design, improve the insulation and air tightness, total air leak rate ≤2.5%;
5, With dynamic balanced double inlet Centrifugal fan, with good air dynamic features, and accurate working, high efficiency, low vibration, low noise etc.
6, High efficient heat exchanger coil, ensure to provide the enough cooling capacity to the unit. And also high efficient breakwater panel is provided if required, water flow in coil ≤3×10-4kg/kg
7, Strong structure, good looking and permanent color.
8, Reasonable inside structure, with the suitable space for maintenance and cleaning.
9, Casing sheet: Provide double-skin construction constructing Sandwich type comprising 0.5mm thick galvanized internal and external skins and with 30mm thick polystyrene insulation of minimum 45kg/m3 density. Good airproof material is use between the casing and the frame to reduce the rate of the air leak.
The combined air handling untis are modular designed ,each modular can be used independently and can also work together and company with fan coil units to add refresh air. Not only reduce operation costs and energy saving, but also optimize air quality and create a congnitive indoor space to meet the human health requirements
rooftop air conditioners application:
The units are widely used in the air system of many inductries like mechanical ,electronic, textile,medical,chemical,energy and foo inductries ,etc. the units are also ideal solution for restaurants, office buildings,hospitals,theaters,supermarkets and palaestra.
rooftop air conditioners structure diagram
1. Conventional
2. Technical purification
3. Heat recovery type
rooftop air conditioners factory
Rooftop air conditioner Structure:
1. Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
2. Direct expansion coils with condensate drain tray.
Hermetic compressor
1. High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
2. Ripple type acoustic insulation for compressor section, and thermal insulation for coil and fan section, low noise.
Centrifugal fan
1. Forward curve centrifugal fans for air treatment section and axial fans for condensation section.
2. Front, side and underside air discharge of the treatment unit.
3. High external pressure, long air supply distance.
Electric panel
1. Electric panel consists of breakers and contactors for compressors and fan motors, phase sequence relay and other necessary protection devices for the main components
2. Easy operation line controller
3. Cooling/Heating/Auto
3. Error indication
4. Timing on/off
Optional
1. Economizer with fresh, return air dampers and fresh air hood
2. Free cooling function for low ambient temperature
3. Low ambient control device for operation of outdoor units at ambient temperatures from less than 20C down to -10C
4. BMS devices
4. T3 (Tropical climate)
5. Condenser coil guard
6. Roof curb
7. Metal / aluminum filter
8. Air pressure switch for indoor fan
9. High static condenser fan option with sealed + drain condensing section
10. Optional water heating coil
11. Metal or plastic mesh on condenser coil
12. Optional supply / return air configurations
13. Upgraded evaporator fan motor drives
14. G4 filter, plate and bag filter