Product Description
Introducing the impressive 2500kW Shenglin Bitcoin Hydro Cooling Container with Adiabatic Dry Cooler - the pinnacle of cooling technology designed specifically for high-efficiency Bitcoin mining operations.
Project 1:
Country: USA Country: USA
Application: Bitcoin immersion cooling system Application: Bitcoin immersion cooling system
Cooling Capacity: 1270kW Cooling Capacity: 117kW
Cooling Medium: BC-888
Cooling Medium: Bitcoin Fluid
Supply Power: 415V/3P/60Hz
Supply Power: 415V/3P/60Hz
Fan Brand: Ziehl-Abegg
Fan Brand: Chinese Brand
Shenglin Bitcoin Hydro Cooling Container with Adiabatic dry cooler Features
- High Efficiency Heat Exchanger: Our heat exchangers are meticulously designed to maximize heat transfer relative to the energy consumed by the fan. With a sophisticated tube and tube coupling design, we ensure a minimal pressure drop in the coil on the media sides (maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic design software, extensively tested and proven in Germany, guarantees superior performance.
- Premium Fans: We select only low specific energy consumption fans. Our fan nozzles are engineered for maximum airflow and air throw. Leveraging the expertise of the world's leading manufacturers, our fans are renowned for operational reliability and longevity. The motors boast an IP 54 protection class and insulation class F, and each fan includes an air separator.
- Built to Last: Our products are designed for enduring, low-maintenance operations. With durable materials and a robust enclosure finished with a hard gloss powder coating, they offer exceptional protection. Both manifolds and U-bends are securely enclosed, and the units are designed for outdoor installation. Each unit undergoes 100% leakage testing at 31 bar.
Shenglin Bitcoin Hydro Cooling Container with Adiabatic dry cooler Options:
1. Coil Design Refrigerant: Water, oil, glycol.
- Multiple circuits.
- Sub-cooling circuits.
- Stainless steel or aluminum casing.
- Coated aluminum or copper fins.
- Explosion-proof motor.
- Customized fin spacing.
Shenglin Bitcoin Hydro Cooling Container with Adiabatic dry cooler Application:
Industrial Field:
p
Cutting-edge Process Engineering: Ideal for heat/power plants, power generation, the chemical industry, air conditioning chillers, heat transformers, immersion cooling for Bitcoin, smelting, and more. Suitable for any equipment requiring heat dissipation and outdoor installation.
Solution A
For Bitcoin mining farms utilizing immersion cooling systems, our dry coolers offer the most cost-effective solution for heat removal. We provide a full range of immersion-optimized dry coolers, from 5kW single-fan units to V-shaped 48-921kW dry coolers. Made in China and tailored to your requirements.
Solution B
For battery or UPS storage rooms (data centers), our dry coolers are the ideal choice to complement precision air conditioning systems for optimal room cooling.
Like this way:
Solution C
For battery or UPS storage rooms (electronic and telecommunication equipment rooms), we offer customized wall-mounted air conditioners designed to meet your specific needs.
Like this way:
Dry Air Cooler Technical Parameter:
Fluid cooler SHSL-D1 Series Parameters (Fin Space: 2.1mm)
Type |
SHSL-D1-005-1x350 |
SHSL-D1-006-1x350 |
SHSL-D1-007-1x350 |
SHSL-D1-009-1x450 |
SHSL-D1-011-1x450 |
SHSL-D1-013-1x450 |
SHSL-D1-014-1x500 |
SHSL-D1-017-1x500 |
SHSL-D1-020-1x500 |
Capacity |
Water |
35ºC outdoor temp. |
Inlet |
45ºC, |
△ |
KW |
4.89 |
5.90 |
6.83 |
9.39 |
10.99 |
13.33 |
14.32 |
17.01 |
19.80 |
outlet |
40ºC |
Y |
20% Glycol |
Inlet |
45ºC |
△ |
4.72 |
5.69 |
6.69 |
8.90 |
10.61 |
13.05 |
13.91 |
16.11 |
19.29 |
outlet |
40ºC |
Y |
Medium |
Water flow |
M3/h |
0.85 |
1.03 |
1.20 |
1.63 |
1.91 |
2.30 |
2.50 |
3.00 |
3.50 |
Pressure drop |
kPa |
36.00 |
31.00 |
58.00 |
25.00 |
40 |
80 |
50 |
60 |
40 |
Air flow |
△ |
M3/h |
2828 |
2712 |
2492 |
6199 |
5827 |
5225 |
8469 |
8168 |
7601 |
Y |
Fan motor |
Phase |
1 |
1 |
1 |
3 |
3 |
3 |
3 |
3 |
3 |
△ |
W |
140 |
140 |
140 |
540 |
540 |
540 |
830 |
830 |
830 |
Y |
△ |
A |
0.60 |
0.60 |
0.60 |
1.10 |
1.10 |
1.10 |
1.45 |
1.45 |
1.45 |
Y |
Fan |
No X φ |
1x1x350 |
1x1x350 |
1x1x350 |
1x1x450 |
1x1x450 |
1x1x450 |
1x1x500 |
1x1x500 |
1x1x500 |
Sound pressure level |
△ |
dB(A) |
31 |
31 |
31 |
43 |
43 |
43 |
49 |
49 |
49 |
Y |
10m |
Dimension |
L |
mm |
870 |
870 |
870 |
1020 |
1020 |
1020 |
1220 |
1220 |
1220 |
W |
mm |
525 |
525 |
525 |
625 |
625 |
625 |
825 |
825 |
825 |
H |
mm |
797 |
797 |
797 |
820 |
820 |
820 |
870 |
870 |
870 |
A |
mm |
690 |
690 |
690 |
840 |
840 |
840 |
1040 |
1040 |
1040 |
B |
mm |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
C |
mm |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
D |
mm |
490 |
490 |
490 |
490 |
490 |
490 |
490 |
490 |
490 |
Inlet φ |
mm |
3/4" |
3/4" |
3/4" |
1" |
1" |
1" |
1-1/4" |
1-1/4" |
1-1/4" |
Inlet φ |
mm |
3/4" |
3/4" |
3/4" |
1" |
1" |
1" |
1-1/4" |
1-1/4" |
1-1/4" |
Product weight(empty) |
kg |
38 |
42 |
48 |
55 |
60 |
67 |
75 |
82 |
91 |
Note: The standard SHSL-D1 remote radiator features a vertical air discharge. For a horizontal air discharge, please add an 'H' in the nomenclature. For example: SHSL-D1-005H-1X350
Shenglin Bitcoin Hydro Cooling Container with Adiabatic dry cooler Parameters
(Fin Space: 2.1mm)
Type |
D2-148-4x630 |
D2-166-4x630 |
D2-175-4x630 |
D2-228-6x630 |
D2-250-6x630 |
D2-276-6x630 |
D2-310-8x630 |
D2-343-8x630 |
D2-364-8x630 |
D2-392-10x630 |
Capacity |
Water |
KW |
147.99 |
165.85 |
175.21 |
227.85 |
250.42 |
276.53 |
309.85 |
342.73 |
364.07 |
391.99 |
20% Et. Glycol |
KW |
142.42 |
161.57 |
170.91 |
219.09 |
244.69 |
270.22 |
301.18 |
333.55 |
354.64 |
383.3 |
Air flow |
M3/h |
76459 |
74341 |
72134 |
114686 |
111511 |
108188 |
152911 |
148675 |
144255 |
191136 |
Fan |
No. X φ |
2x2x630 |
2x2x630 |
2x2x630 |
2x3x630 |
2x3x630 |
2x3x630 |
2x4x630 |
2x4x630 |
2x4x630 |
2x5x630 |
Fan motor 400/3N/50HZ |
A |
20.4 |
20.4 |
20.4 |
30.6 |
30.6 |
30.6 |
40.8 |
40.8 |
40.8 |
51.00 |
Sound pressure level |
dB(A)10m |
64 |
64 |
64 |
66 |
66 |
66 |
67 |
67 |
67 |
68 |
Dimension |
L |
mm |
2186 |
2186 |
2186 |
3250 |
3250 |
3250 |
4250 |
4250 |
4250 |
5250 |
H |
mm |
1874 |
1874 |
1874 |
1874 |
1874 |
1874 |
1874 |
1874 |
1874 |
1874 |
D |
mm |
2100 |
2100 |
2100 |
2100 |
2100 |
2100 |
2100 |
2100 |
2100 |
2100 |
D1 |
mm |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
L1 |
mm |
963 |
963 |
963 |
963 |
963 |
963 |
963 |
963 |
963 |
963 |
L2 |
mm |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
L3 |
mm |
1963 |
1963 |
1963 |
2963 |
2963 |
2963 |
3963 |
3963 |
3963 |
4963 |
Connections inlet φ |
mm |
2XDN50 |
2XDN65 |
2XDN65 |
2XDN65 |
2XDN80 |
2XDN80 |
2XDN80 |
2XDN80 |
2XDN100 |
2XDN100 |
Connections onlet φ |
mm |
2XDN50 |
2XDN65 |
2XDN65 |
2XDN65 |
2XDN80 |
2XDN80 |
2XDN80 |
2XDN80 |
2XDN100 |
2XDN100 |
Product weight(empty) |
kg |
769 |
811 |
853 |
1134 |
1197 |
1261 |
1498 |
1589 |
1673 |
1864 |