Chiller Water Fan Coil Unit for HVAC Systems Cassette Ceiling Fan Coil

Product Details
Customization: Available
Type: Fan Coil Unit
Air Tube Material: Galvanized Sheet
Still deciding? Get samples of US$ 200/Piece
Request Sample
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (20)
  • Chiller Water Fan Coil Unit for HVAC Systems Cassette Ceiling Fan Coil
  • Chiller Water Fan Coil Unit for HVAC Systems Cassette Ceiling Fan Coil
  • Chiller Water Fan Coil Unit for HVAC Systems Cassette Ceiling Fan Coil
  • Chiller Water Fan Coil Unit for HVAC Systems Cassette Ceiling Fan Coil
Find Similar Products

Basic Info.

Corrosion Durability
Higher
Operating Voltage
230 VAC
Noise Level
Low
Application Fields
Mechanical Engineering
Mounting
Ceiling Mount
Lifetime
15~20 years
Certification
RoHS, ISO, CE, CCC
Condition
New
Tube Quantity
1, 2, 4
Volage
220V/1p/50Hz
Core
Tube Fin Heat Exchanger
Fin Material
Hydrophilic Aluminum Foil
Tube Material
Copper Tube
Transport Package
Wooden Box and Carton Box
Specification
Customized
Trademark
Shenglin
Origin
Shanghai, China
HS Code
84158120
Production Capacity
25000PCS/Month

Product Description

Chiller Water Fan Coil Unit for HVAC Systems Cassette Ceiling Fan Coil
.
Feature:
1. Compact structure and thin casing ( only 130mm thickness ) leave more space for your room
2. The use of cross-flow fan combined with newly wind-guiding technology makes lower noise and you can enjoy a healthier and more comfortable sleep
3. With module-noble&fashion arc frame and color-elegant&graceful show white, it will be inviting wherever it is in your room.


Technical Specifications
1. Ceiling & Floor Type Fan Coil Unit
2. Cooling capacityW2700
3. Heating capacityW4050
4. Air volumem3/h510
5. Power supply220V/1/50Hz
6. Power inputW45
7. Room ThermostatRemote controller
8. Remarkremote controller, 2 tubes
9. Net dimensions (W X H X D)mm905*673*243
10. Packing dimensions(W X H X D)mm995*765*311
11. Net weightkg30
12. Gross weightkg33

Duct type fan coil unit specification:
 
model(2 tube system) MFP-34WA-B MFP-51WA-B MFP-68WA-B MFP-85WA-B MFP-102WA-B MFP-136WA-B MFP-170WA-B MFP-204WA-B MFP-238WA-B
power supply 220V,50Hz,1Ph  
air volume H m3/h 340 510 680 850 1020 1360 1700 2040 2380
M 270 380 515 660 765 1040 1280 1550 1800
L 190 260 340 430 530 710 860 1050 1280
static pressure Pa 12(30,50) 12(30,50) 12(30,50) 12(30,50) 12(30,50) 12(30,50) 12(30,50) 12(30,50) 12(30,50)
cooling capacity TH H W 2150 3200 4000 5000 5800 8000 9500 11300 12800
BTU/h 7335 10918 13648 17060 19789 27296 32414 38555 43673
SH W 1530 2230 2850 3530 4230 5790 6850 8110 9140
BTU/h 5220 7608 9724 12044 14432 19755 23372 27671 31185
TH M W 1710 2510 3305 4090 4790 6660 7695 9153 10000
SH W 1210 1715 2320 2890 3345 4715 5470 6340 7165
TH L W 1355 2000 2470 3000 3520 5150 5870 6820 7850
SH W 980 1420 1735 2020 2500 3530 4075 4950 5580
heating capacity H W 3350 5050 6250 7900 9150 12500 15100 17800 20100
M W 2650 3900 5100 6350 7400 10300 11950 14200 15500
L W 2100 3100 3850 4650 5450 8000 9100 10550 12150
noise high speed 12Pa dB(A) 37 39 41 43 45 47 48 50 52
30Pa 39 41 43 45 48 49 50 52 54
50Pa 42 44 46 47 49 50 52 54 56
power input 12Pa W 37 52 62 76 96 134 152 189 228
30Pa 44 59 72 87 108 156 174 212 253
50Pa 49 66 84 100 118 174 210 250 300
waterflow volume   m3/h 0.37 0.55 0.69 0.86 0.99 1.37 1.63 1.94 2.19
water pressure dropping kPa 16 22 18 29 22 27 35 37 38
dimension of water(in & out)connection pipe   ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
  ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
coil type high efficient copper pipe to wear Hydrophilic aluminum coil
dimension of water drain pipe mm ZG3/4"
dimension without air return box mm(L*W*H) 624×465×235 814×465×235 864×465×235 944×465×235 1044×465×235 1424×465×235 1474×465×235 1674×465×235 1824×465×235
air return from side 624×510×235 814×510×235 864×510×235 944×510×235 1044×510×235 1424×510×235 1474×510×235 1674×510×235 1824×510×235
air return from bottom 624×492×252 814×492×252 864×492×252 944×492×252 1044×492×252 1424×492×252 1474×492×252 1674×492×252 1824×492×252
weight   kg 11 13 14 16 17 26 29 32 34


Cassette type fan coil unit specification:
 
model(2 tube system) MFP-34KM-(Q)MK1 MFP-51KM-(Q)MK1 MFP-68KM-(Q)MK1 MFP-85KM-(Q)MK2 MFP-102KM-(Q)MK2 MFP-136KM-(Q)MK3 MFP-170KM-(Q)MK3 MFP-204KM-(Q)MK3 MFP-238KM-(Q)MK3
model FP-34KM-(Q)M1 FP-51KM-(Q)M1 FP-68KM-(Q)M1 FP-85KM-(Q)M2 FP-102KM-(Q)M2 FP-136KM-(Q)M3 FP-170KM-(Q)M3 FP-204KM-(Q)M3 FP-238KM-(Q)M3
model of panel MB-SD11K1 MB-SD11K2 MB-SD11K3
power supply 220V,50Hz,1Ph
air volume H m3/h 380 550 680 880 1050 1380 1750 2050 2200
M 300 440 540 700 840 1100 1400 1640 1760
L 230 330 410 530 630 830 1050 1230 1320
static pressure Pa 0 0 0 0 0   0 0 0
cooling capacity TH H W 2000 3000 3800 4900 5800 7500 9800 11000 12000
BTU/h 6824 10236 12966 16719 19790 25590 33438 37532 40944
SH W 1400 2200 2850 3500 4250 5500 7150 8250 9100
BTU/h 4777 7506 9724 11942 14501 18766 24396 28149 31049
TH M W 1700 2550 3250 4150 4950 6400 8350 9350 10200
SH W 1150 1800 2350 2850 3500 4550 5950 6850 7650
TH L W 1400 2050 2600 3400 4000 5200 6750 7600 8300
SH W 950 1400 1850 2300 2800 3600 4700 5450 6000
heating capacity H W 3100 4700 5900 7600 9000 11600 15200 17100 18600
M W 2650 4000 5000 6450 7650 9850 12900 14550 15800
L W 2100 3150 3950 5100 6050 7750 10200 11450 12450
noise H 0Pa dB(A) 39 42 44 42 46 46 47 50 51
power input H 0Pa W 40 50 58 70 95 130 160 190 210
waterflow volume m3/h 0.34 0.51 0.65 0.83 0.99 1.28 1.67 1.87 2.04
water pressure dropping kPa 11 13 22 18 25 23 28 33 42
dimension of water(in & out)connection pipe in ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
out ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
coil type high efficient copper pipe to wear Hydrophilic aluminum coil
dimension of water drain pipe mm ¢26 ¢26 ¢26 ¢26 ¢26   ¢26 ¢26 ¢26
net dimension unit L×W×H     mm 592*592*242 750*750*242 840*840*242 840*840*292
panel 650*650*40 850*850*40 950*950*40 950*950*40
net weight unit kg 17 18 18 22 23 25 26 27 27
  panel   2.2 4.2 5

Chiller Water Fan Coil Unit for HVAC Systems Cassette Ceiling Fan Coil
Chiller Water Fan Coil Unit for HVAC Systems Cassette Ceiling Fan Coil
Chiller Water Fan Coil Unit for HVAC Systems Cassette Ceiling Fan Coil
Chiller Water Fan Coil Unit for HVAC Systems Cassette Ceiling Fan Coil
Chiller Water Fan Coil Unit for HVAC Systems Cassette Ceiling Fan Coil
Chiller Water Fan Coil Unit for HVAC Systems Cassette Ceiling Fan Coil
Chiller Water Fan Coil Unit for HVAC Systems Cassette Ceiling Fan Coil
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier