260kw Data Center Liquid Cooling Cdu with Redundant Pumps

  • Audited Supplier
  • 17 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of 260kw Data Center Liquid Cooling Cdu with Redundant Pumps

260kw Data Center Liquid Cooling Cdu with Redundant Pumps
260kw Data Center Liquid Cooling Cdu with Redundant Pumps pictures & photos
260kw Data Center Liquid Cooling Cdu with Redundant Pumps
260kw Data Center Liquid Cooling Cdu with Redundant Pumps pictures & photos
260kw Data Center Liquid Cooling Cdu with Redundant Pumps
260kw Data Center Liquid Cooling Cdu with Redundant Pumps pictures & photos
260kw Data Center Liquid Cooling Cdu with Redundant Pumps
260kw Data Center Liquid Cooling Cdu with Redundant Pumps pictures & photos
260kw Data Center Liquid Cooling Cdu with Redundant Pumps
260kw Data Center Liquid Cooling Cdu with Redundant Pumps pictures & photos
260kw Data Center Liquid Cooling Cdu with Redundant Pumps
260kw Data Center Liquid Cooling Cdu with Redundant Pumps pictures & photos
260kw Data Center Liquid Cooling Cdu with Redundant Pumps
  • 260kw Data Center Liquid Cooling Cdu with Redundant Pumps
  • 260kw Data Center Liquid Cooling Cdu with Redundant Pumps
    260kw Data Center Liquid Cooling Cdu with Redundant Pumps
  • 260kw Data Center Liquid Cooling Cdu with Redundant Pumps
    260kw Data Center Liquid Cooling Cdu with Redundant Pumps
  • 260kw Data Center Liquid Cooling Cdu with Redundant Pumps
    260kw Data Center Liquid Cooling Cdu with Redundant Pumps
  • 260kw Data Center Liquid Cooling Cdu with Redundant Pumps
    260kw Data Center Liquid Cooling Cdu with Redundant Pumps
  • 260kw Data Center Liquid Cooling Cdu with Redundant Pumps
    260kw Data Center Liquid Cooling Cdu with Redundant Pumps
  • 260kw Data Center Liquid Cooling Cdu with Redundant Pumps
    260kw Data Center Liquid Cooling Cdu with Redundant Pumps

Find Similar Products

Product Description


High-Efficiency Coolant Distribution Unit (CDU) for Data Center Cooling
Product Description

The Coolant Distribution Unit (CDU) is the central component of the water cooling system, responsible for efficiently distributing the cooling medium to meet the cooling needs of various applications. It ensures the system operates stably by incorporating additional monitoring and support devices. The CDU on the secondary side of the heat exchange unit is primarily used for controlling heat exchange in liquid cooling heat sink systems. This system includes a frequency conversion circulating pump, plate heat exchanger, electric control valve, temperature sensor, pressure sensor, filter, expansion tank, flow meter, and online liquid replenishment function. It is pre-installed and tested at the factory to reduce on-site workloads.

260kw Data Center Liquid Cooling Cdu with Redundant Pumps260kw Data Center Liquid Cooling Cdu with Redundant Pumps

Performance range

· Heat transfer quantity:350~1500kW
 

Complete CDU System technical parameter
20-80KW CDU technical parameters
Indoor unit models   CDU020W CDU030W CDU040W CDU050W CDU060W CDU070W CDU080W
main power supply 220V/1Ph/50Hz  
Unit performance parameters
Primary side 35/42 ° C
Secondary side 40/47 ° C
Heat exchange capacity-kw 21.1 32.2 41.3 53.2 62.5 70.6 82.1
Secondary side flow rate - m3/h 2.58 3.94 5.06 6.51 7.65 8.64 10.05
Primary side flow rate - m3/h 2.58 3.94 5.06 6.51 7.65 8.64 10.05
Rated power of the unit - kW 0.46 0.59 0.73 0.83 0.91 1.00 1.13
Unit FLA-A 4.26 4.26 4.26 5.97 5.97 5.97 8.81
Primary side 35/45 ° C,
Secondary side 40/50 ° C
Heat exchange capacity-kw 17.1 26.1 33.5 43.1 50.6 57.2 66.5
Primary side medium Softened water, ethylene glycol solution
Secondary side medium Deionized water, coolant
Performance parameters of circulating pump
circulating pump qty 1 or 1+1 redundancy
Rated power of circulating pump - kW   0.41 0.54 0.68 0.78 0.86 0.95 1.08
Connection pipe size specifications
Primary side pipeline   DN32 DN32 DN32 DN40 DN40 DN40 DN40
Secondary side pipeline   DN32 DN32 DN32 DN40 DN40 DN40 DN40
Interface type   Clamp Clamp Clamp Clamp Clamp Clamp Clamp
Unit size and weight
Unit width-mm   600 600 600 600 600 600 600
Unit depth-mm   1200 1200 1200 1200 1200 1200 1200
Unit height-mm   2000 2000 2000 2000 2000 2000 2000
weight-kg   200 200 200 200 200 200 200
Recommended specifications for circuit breakers and cables
Recommended Circuit Breaker Specifications-A   16 16 16 16 16 16 16
Recommended cable specification - mm2   3*2.5 3*2.5 3*2.5 3*2.5 3*2.5 3*2.5 3*2.5


260kw Data Center Liquid Cooling Cdu with Redundant Pumps260kw Data Center Liquid Cooling Cdu with Redundant Pumps

Features

· 10-inch touch screen, multi-level authority control;

· Modular design, can be increased according to the demand;

· (Optional) Double back-up high-efficiency frequency conversion pump automatically adjusts the flow rate according to the loaded condition;

· (Optional) Dual power supply backup;

· Corrosion-resistant 304 stainless steel and above material piping components;

· Standard Shenglin liquid-cooled data center function control system, temperature monitoring, secondary side temperature control, flow and differential pressure control, anti-condensation protection, conductivity monitoring (optional), water turbidity monitoring (optional), water hardness monitoring (optional), PH value monitoring (optional);

· Ultra-quiet motor, low noise, long service life;

· Standard Modbus TCP communication protocol, rich detection, alarm and protection functions in the system, automatic protection of the setup parameters, power-down will not lose the operating parameters and alarm records;

· Provide standard communication protocol, can be customized according to customer demand for special format monitoring protocol;

· Secondary side filtration precision: 25~100 (μm) ultra-wide design range.


Our Advantages
    With Shenglin's cutting-edge design, the CDU enhances the efficiency and dependability of the water cooling system. It boasts six channels that link the main pipeline to the secondary water separator of the water-cooled cabinet, eliminating installation and production errors with the use of clamps and rubber hoses.

    Shenglin's CDU features a multi-stage centrifugal pump for circulating industrial water, ensuring a smooth and reliable flow of coolant. An expansion tank is integrated into the CDU to compensate for temperature fluctuations, maintaining consistent pressure levels and ensuring the system's reliable operation.

    To prevent issues like oxidation corrosion, inadequate circulation, and cavitation of the circulation pump, Shenglin's CDU includes an automatic air vent valve on the top of the makeup water tank/main pipeline. This valve promptly eliminates non-condensable gases from the system.

    Furthermore, Shenglin's CDU is equipped with a 150μm filter in its main path to preserve the quality of the coolant, guaranteeing the steady and secure operation of the entire system.

260kw Data Center Liquid Cooling Cdu with Redundant Pumps

260kw Data Center Liquid Cooling Cdu with Redundant Pumps260kw Data Center Liquid Cooling Cdu with Redundant PumpsNote: for further information please send me email.

Ms. Echo Lee

 
 
 

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR2341224". Items marked "verified" are certified.

Watch Video
Watch Video
Shanghai Shenglin M&E Technology Co., Ltd.
Shanghai Shenglin M&E Technology Co., Ltd.
Shanghai Shenglin M&E Technology Co., Ltd.
Shanghai Shenglin M&E Technology Co., Ltd.
Shanghai Shenglin M&E Technology Co., Ltd.
Shanghai Shenglin M&E Technology Co., Ltd.
Shanghai Shenglin M&E Technology Co., Ltd.
Shanghai Shenglin M&E Technology Co., Ltd.

About Our Factory & Business Background

Address
Room B321, Building 1, No. 619, Longchang Road, Yangpu District, Shanghai, China
Terms of Payment
T/T, Western Union
International Commercial Terms(Incoterms)
FOB, CFR, CIF, DDP, EXW
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
Nearest Port
Shanghai, Ningbo

Our Production Capability & Technical Expertise

Main Products
Dry Cooler, Immersion Cooling, Heat Exchanger, Condenser, Chiller, Rooftop Air Conditioner, Heat Pump, Ahu, Condensing Unit, Cold Room System

Our Industry Experience & Global Business Record

Export Year
2009-12-29
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now