Precision air conditioner
Features
1.Cooling capacity: 7.5KW-93.6KW
2.Refrigerant: R22
(R407C/R410A
)
3.Digital control mode, can reach high accuracy.
4.Keep the dust, oil fog and moisture from entering the internal of the equipments.
5.The structure design makes the installation more flexible. And the unit can be installed perfectly in the side or outside wall of the equipment.
6.Totally solve dust and moisture contamination issues caused by ventilation.
7.Widely used in telecommunications, broadcasting, electricity, automation and other industries out-door cabinet, IDC room cooling needs.
Technical Data
GT-HFM series constant temperature and humidity precision air conditioner specification 1 |
Model GT-HFM-() |
07 |
12 |
15 |
18 |
20 |
24 |
27 |
30 |
Specification |
Total cooling capacity |
kW |
7.5 |
12.6 |
15.3 |
18.6 |
21.8 |
24.2 |
27.5 |
31.8 |
Sensible cooling capacity |
kW |
6.9 |
11.7 |
14.1 |
17.4 |
20.2 |
22.4 |
25 |
29.5 |
Electric heating |
kW |
3 |
6 |
6 |
9 |
9 |
9 |
12 |
15 |
Air volume 2* |
m3/h |
1800 |
3250 |
4100 |
5200 |
5400 |
6600 |
7500 |
9000 |
Outlet air pressure 2* |
Pa |
25 |
25 |
25 |
50 |
50 |
75 |
75 |
75 |
Noise 3* |
dB(A) |
54 |
54 |
55 |
56 |
56 |
56 |
56 |
56 |
Temperature control range and accuracy |
ºC |
18~28,±1 |
Humidity control range and accuracy |
% |
45~70,±5 |
Power |
3N-380V-50Hz |
Input power 4* |
kW |
6 |
11 |
12.6 |
16.8 |
17.5 |
19 |
23.9 |
28.9 |
Indoor unit |
Supply air fan |
type |
low noise centrifugal type |
capacity |
kW |
0.32 |
0.55 |
0.75 |
1.1 |
1.1 |
1.5 |
2.2 |
2.2 |
Electrode humidifier |
humidification volume |
kg/h |
3 |
3 |
5 |
5 |
5 |
8 |
8 |
8 |
Electric heating |
capacity |
kW |
3 |
6 |
6 |
9 |
9 |
9 |
12 |
15 |
Evaporator type |
Inner grooved copper tube and aluminum fin |
Air filter |
primary efffect plate type filter |
Dimension |
L |
mm |
950 |
1200 |
1200 |
1200 |
1200 |
1600 |
1600 |
1600 |
W |
mm |
580 |
680 |
680 |
680 |
680 |
780 |
780 |
780 |
H |
mm |
1800 |
1880 |
1880 |
1880 |
1880 |
2000 |
2000 |
2200 |
Weight |
kg |
190 |
230 |
270 |
290 |
300 |
400 |
430 |
510 |
Outdoor unit |
Model GT-( )*quantity |
WL08*1 |
WL12*1 |
WL15*1 |
WL18*1 |
WL20*1 |
WL25*1 |
WL27*1 |
WL30*1 |
compressor |
type |
Totally enclosed scroll type |
quantity |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
condenser type |
Inner grooved copper tube and aluminum fin |
Condensing fan |
type |
Low noise axial type |
capacity |
kW |
0.37 |
0.37 |
0.37 |
0.55 |
0.55 |
0.55 |
0.75 |
0.75 |
Dimension |
L |
mm |
800 |
850 |
850 |
980 |
980 |
980 |
980 |
980 |
W |
mm |
800 |
850 |
850 |
980 |
980 |
980 |
980 |
980 |
H |
mm |
980 |
1080 |
1080 |
1080 |
1080 |
1080 |
1234 |
1234 |
Weight |
kg |
90 |
120 |
150 |
170 |
170 |
205 |
210 |
220 |
Freon 5* |
type |
R22(R407C/R410A) |
control method |
Out balance expansion valve |
Collecting pipe 6* |
liquid pipe`s diameter |
mm |
9.52(9.52) |
12.7(9.52) |
12.7(9.52) |
15.88 (12.7) |
15.88 (12.7) |
15.88 (12.7) |
15.88 (12.7) |
15.88 (12.7) |
gas pipe`s diameter |
mm |
15.88(12.7) |
19.05(15.88) |
19.05 ( 15.88) |
22.23 (19.05) |
22.23 (19.05) |
28.6 (22.23) |
28.6 (22.23) |
28.6 (22.23) |
Model GT-HFM-() |
35 |
40 |
50 |
55 |
60 |
70 |
80 |
90 |
|
HP |
|
|
6*2 |
7*2 |
8*2 |
9*2 |
10*2 |
6*4 |
7*4 |
8*4 |
The unit features |
The total capacity |
kW |
36.5 |
42.1 |
49.1 |
54.1 |
61 |
71.6 |
81.4 |
93.6 |
Show the capacity |
kW |
33.8 |
38.4 |
44.3 |
49.8 |
55.5 |
65.1 |
74.7 |
85.1 |
Sensible heat factor |
0.926027397 |
0.912114014 |
0.902240326 |
0.92051756 |
0.909836066 |
0.909217877 |
0.917690418 |
0.909188034 |
Electric heating |
kW |
15 |
18 |
18 |
18 |
24 |
24 |
30 |
30 |
Air volume 2* |
m3/h |
10500 |
11500 |
13000 |
15500 |
18000 |
20500 |
22000 |
25000 |
Cooling capacity per airflow ratio |
287.6712329 |
273.1591449 |
264.7657841 |
286.5064695 |
295.0819672 |
286.3128492 |
270.2702703 |
267.0940171 |
Closed to static pressure 2* |
Pa |
75 |
75 |
75 |
75 |
100 |
100 |
125 |
125 |
The unit noise 3* |
dB(A) |
56 |
58 |
58 |
58 |
58 |
58 |
60 |
60 |
Temperature control range and precision |
ºC |
18~28,±1 |
ShiKong range and precision |
% |
45~70,±5 |
The power supply |
3N-380V-50Hz |
The input power 4* |
kW |
30 |
38.2 |
39.6 |
40.7 |
52.3 |
56.7 |
66.8 |
74.8 |
Indoor machine |
blower |
Type |
Low noise centrifugal more wings |
power |
kW |
2.2 |
3 |
3 |
4 |
5.5 |
7.5 |
7.5 |
11 |
The electrode humidifier |
Humidification quantity |
kg/h |
13 |
13 |
13 |
15 |
15 |
15 |
18 |
21 |
Electric heating |
power |
kW |
15 |
18 |
18 |
18 |
24 |
24 |
30 |
30 |
The evaporator form |
Efficient internal thread copper aluminum type |
Air filter |
At the beginning of plate filter |
Installation dimensions |
L |
mm |
1800 |
1800 |
2000 |
2000 |
2000 |
2200 |
2200 |
2500 |
W |
mm |
850 |
850 |
850 |
850 |
850 |
1080 |
1080 |
1200 |
H |
mm |
2200 |
2200 |
2150 |
2150 |
2150 |
2350 |
2350 |
2450 |
weight |
kg |
580 |
610 |
710 |
750 |
820 |
900 |
980 |
1250 |
outdoor unit |
Model GT-( )* quantity |
WL35*1 |
WL40*1 |
WL50*1 |
WL55*1 |
WL60*1 |
WL70*1 |
WL40*2 |
WL50*2 |
compressor |
Type |
Efficient closed vortex type |
quantity |
1 |
2 |
2 |
2 |
2 |
2 |
4 |
4 |
Condenser form |
Efficient internal thread copper aluminum type |
condensate fan |
Type |
low-noise axial fan |
power |
kW |
0.75 |
0.55*2 |
0.55*2 |
0.55*2 |
0.75*2 |
0.75*2 |
0.55*4 |
0.55*4 |
Installation dimensions |
L |
mm |
980 |
1880 |
1880 |
1880 |
1880 |
1880 |
1880 |
1880 |
W |
mm |
980 |
980 |
980 |
980 |
980 |
980 |
980 |
980 |
H |
mm |
1234 |
1080 |
1080 |
1080 |
1234 |
1234 |
1080 |
1080 |
weight |
kg |
250 |
320 |
400 |
400 |
450 |
500 |
320*2 |
400*2 |
refrigerant 5* |
Type |
R22(R407C/R410A) |
type of control |
Balanced expansion valve |
Connecting pipe6* |
Fluid pipe diameter |
mm |
15.88 (12.7) |
15.88*2 (12.7*2) |
15.88*2 (12.7*2) |
15.88*2 (12.7*2) |
15.88*2 (12.7*2) |
15.88*2 (12.7*2) |
15.88*4 (12.7*4) |
15.88*4 (12.7*4) |
Pipe diameter |
mm |
34.9 (28.6) |
22.23*2 (19.05*2) |
28.6*2 (22.23*2) |
28.6*2 (22.23*2) |
28.6*2 (22.23*2) |
34.9*2 (28.6*2) |
22.23*4 (19.05*4) |
28.6*4 (22.23*4) |
1.Cooling conditions: Indoor dry bulb / wet bulb temperature 24/17 ºC; outdoor dry bulb / wet bulb temperature 35/24 ºC;
2.Table stroke volume, static pressure standard parameters can be designed according to customer requirements;
3.Noise is measured as the distance of the indoor unit 3 m free-space data obtained;
4.Input power is the maximum power consumption conditions;
5.Height: hooded type / Duct type;
6.R407C or R410A environmental refrigerant can be used, please specify in the order;
7.Brackets R410A size over size.
Diagrammatic sketch
Application
- server room,computer room