2024 Better Commercial Rooftop Air Conditioner with Heat Recovery

Product Details
Customization: Available
After-sales Service: Online Service
Warranty: 1 Year
Still deciding? Get samples of US$ 2000/Piece
Request Sample
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (20)
  • 2024 Better Commercial Rooftop Air Conditioner with Heat Recovery
  • 2024 Better Commercial Rooftop Air Conditioner with Heat Recovery
  • 2024 Better Commercial Rooftop Air Conditioner with Heat Recovery
  • 2024 Better Commercial Rooftop Air Conditioner with Heat Recovery
  • 2024 Better Commercial Rooftop Air Conditioner with Heat Recovery
  • 2024 Better Commercial Rooftop Air Conditioner with Heat Recovery
Find Similar Products

Basic Info.

Model NO.
WRF32ZA
Corrosion Durability
Higher
Operating Voltage
380/400 VAC
Noise Level
Low
Mounting
Floor Standing
Lifetime
>20 years
Certification
RoHS, ISO, CE
Condition
New
Housing Material
Stainless Steel, Coated Metal
Refrigerant
R22/R134A/R417A/R407c/R404A/R410A
Performance
Cooling/Heating
Keywords
Rooftop Air Conditioner
Transport Package
Wooden Packing
Specification
ROHS, BV, SGS, ISO
Trademark
Shenglin
Origin
Shanghai, China
HS Code
8415909000
Production Capacity
10000 Unit/Units / Month

Product Description

2024 Better Commercial Rooftop Air Conditioner with Heat Recoveryair rooftop air conditioner 
Model WRF12ZA WRF 15ZA WRF18ZA WRF24ZA WRF30ZA WRF 35ZA
WF12ZA WF 15ZA WF18ZA WF24ZA WF30ZA WF 35ZA
Cooling capacity kW 12 15.2 17.5 24 30.3 35.6
Heating capacity kW 13.2 16.6 18.4 26.5 33.3 37.7
Energy regulation
 
% 0,100% 0,50,100%
Power 380V / 3Ph / 50HZA
Cooling input capacity kW 4.1 5.3 5.5 8.8 11.3 12.3
Heating input capacity kW 3.8 4.8 5.1 8.2 10.4 11.3
Start current A 48 62 63 63 74 76
Cooling running current A 7.4 9.7 10.2 16.1 21.2 23.3
Heating running current A 6.9 9.2 9.7 15.1 20.1 22.2
Throttling method
 
Thermal expansion valve
 
Cooling system 1 1 1 1 2 2
Refrigerant R410A
Compressor Compressor type Hermetic scroll compressor
 
Qty 1 1 1 1 2 2
Condensation side
 
 
Condenser Type Copper tube and aluminum fin
Qty 1 1 1 1 1 1
Drive type Direct drive
Motor power kW 0.25 0.37 0.37 0.55 0.75 0.75
Air volume m/h  4600 7800 7800 9000 12600 12600
Evaporation side
 
 
Evapotator Type Copper tube and aluminum fin
Qty 1 1 1 1 1 1
Motor power kW 0.32 0.37 0.45 1.1 1.5 2.2
Air volume m/h 2100 2600 3400 4100 5200 6300
Drive type Direct drive Pulley
Static pressure(Pa) 100 100 100 200 200 250
Filter Aluminum filter G3
Noise dB(A) 67 67 68 71 72 72
Refrigerant filling volume(kg) 3.1 3.1 4.3 2x3.1 2x3.1 2x4.3
External dimension L mm 1410 1410 1410 1978 1978 1978
W mm 1100 1100 1100 1175 1175 1175
H mm 1095 1095 1095 1095 1095 1095
Weight kg 240 260 290 420 480 500

rooftop air conditioner feature: 
1, Complying with above China Standard, which is from ARI standard. ISO9001 and ISO14001 qualified.
2, Choose best materials, main components are from China top brand or imported.
3, The modular casing design, easy interchanging each other. easy install,easy transport,easy maintaince.
4, Unique no-cold-bridge design, improve the insulation and air tightness, total air leak rate ≤2.5%;
5, With dynamic balanced double inlet Centrifugal fan, with good air dynamic features, and accurate working, high efficiency, low vibration, low noise etc. 
6, High efficient heat exchanger coil, ensure to provide the enough cooling capacity to the unit. And also high efficient breakwater panel is provided if required, water flow in coil ≤3×10-4kg/kg
7, Strong structure, good looking and permanent color.
8, Reasonable inside structure, with the suitable space for maintenance and cleaning.
9, Casing sheet: Provide double-skin construction constructing Sandwich type comprising 0.5mm thick galvanized internal and external skins and with 30mm thick polystyrene insulation of minimum 45kg/m3 density. Good airproof material is use between the casing and the frame to reduce the rate of the air leak.
The combined air handling untis are modular designed ,each modular can be used independently and can also work together and company with fan coil units to add refresh air. Not only reduce operation costs and energy saving, but also optimize air quality and create a congnitive indoor space to meet the human health requirements

2024 Better Commercial Rooftop Air Conditioner with Heat Recovery




2024 Better Commercial Rooftop Air Conditioner with Heat Recovery
 

rooftop air conditioner Application:

The units are widely used in the air system of many inductries like mechanical ,electronic, textile,medical,chemical,energy and foo inductries ,etc. the units are also ideal solution for restaurants, office buildings,hospitals,theaters,supermarkets and palaestra.

rooftop air conditioner structure diagram

1. Conventional

2024 Better Commercial Rooftop Air Conditioner with Heat Recovery



2. Technical purification

2024 Better Commercial Rooftop Air Conditioner with Heat Recovery

3. Heat recovery type

2024 Better Commercial Rooftop Air Conditioner with Heat Recovery


Our factory

2024 Better Commercial Rooftop Air Conditioner with Heat Recovery
 

2024 Better Commercial Rooftop Air Conditioner with Heat Recovery
2024 Better Commercial Rooftop Air Conditioner with Heat Recovery

2024 Better Commercial Rooftop Air Conditioner with Heat Recovery


2024 Better Commercial Rooftop Air Conditioner with Heat Recovery
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier