• Service Room Dx Inrow Air Conditioner
  • Service Room Dx Inrow Air Conditioner
  • Service Room Dx Inrow Air Conditioner
  • Service Room Dx Inrow Air Conditioner
  • Service Room Dx Inrow Air Conditioner
  • Service Room Dx Inrow Air Conditioner

Service Room Dx Inrow Air Conditioner

Type: Inrow Air Conditioner
Air Tube Material: Galvanized Sheet
Corrosion Durability: Higher
Operating Voltage: 380/400 VAC
Noise Level: Low
Application Fields: Mechanical Engineering
Samples:
US$ 6142/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory, Trading Company
Diamond Member Since 2010

Suppliers with verified business licenses

Shanghai, China
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (19)

Basic Info.

Model NO.
Gt-Hfm-50
Mounting
Floor Standing
Lifetime
10~15 years
Certification
RoHS, CE
Condition
New
Air Supply Method
Upper Supply and Bottom Return and Bottom Supply a
Evaporator Type
Inner Grooved Copper Tube and Aluminum Fin
Compressor Type
Totally Enclosed Scroll Type
Refrigerant
R410A,R407c,R22
Total Cooling Capacity
21.8 Kw
Air Volume
5400 M3/H
Input Power
17.5kw
Size
1200*680*1880
Application 1
Mobile Base Station
Application 2
Outdoor Rooms
Application 3
Satellite Ground Station
Application 4
Paging Machine Room
Application 5
Network Management Center
Application 6
Small Computer Room
Application 7
Small Laboratory
Transport Package
Customerized Packing
Specification
RoHs, SGS
Trademark
Shenglin
Origin
Shanghai, China(Mainland)
HS Code
8415830000
Production Capacity
1000units/Month

Product Description

Service Room DX Inrow Air Conditioner

Inrow Air Conditioner Description:

Constant temperature and humidity air conditioning is a sophisticated environmental control system, according to the requirement of the environment, you can configure different component implementation refrigeration, heating and humidification. Meet the requirements of precision equipment or sensitive to the environment.
constant temperature and humidity precision air conditioner spec 
Model  GT-HFM-() 07 12 15 18 20 24 27 30 35 40 50 55 60 70 80 90
Total cooling capacity kW 7.5 12.6 15.3 18.6 21.8 24.2 27.5 31.8 36.5 42.1 49.1 54.1 61 71.6 81.4 93.6
Sensible cooling capacity kW 6.9 11.7 14.1 17.4 20.2 22.4 25 29.5 33.8 38.4 44.3 49.8 55.5 65.1 74.7 85.1
Electric heating kW 3 6 6 9 9 9 12 15 15 18 18 18 24 24 30 30
Air volume 2* m3/h 1800 3250 4100 5200 5400 6600 7500 9000 10500 11500 13000 15500 18000 20500 22000 25000
Outlet air pressure 2* Pa 25 25 25 50 50 75 75 75 75 75 75 75 100 100 125 125
Noise 3* dB(A) 54 54 55 56 56 56 56 56 56 58 58 58 58 58 60 60
Temperature control range and accuracy C 18~28,±1
Humidity control range and accuracy % 45~70,±5
Power 3N-380V-50Hz
Input power 4* kW 6 11 12.6 16.8 17.5 19 23.9 28.9 30 38.2 39.6 40.7 52.3 56.7 66.8 74.8

Service Room Dx Inrow Air Conditioner
Inrow Air Conditioner features:
1.Cooling capacity: 7.5KW-93.6KW
2.Refrigerant: R22(R407C/R410A)
3.Digital control mode, can reach high accuracy.
4.Keep the dust, oil fog and moisture from entering the internal of the equipments.
5.The structure design makes the installation more flexible. And the unit can be installed perfectly in the side or outside wall of the equipment.
6.Totally solve dust and moisture contamination issues caused by ventilation.
7.Widely used in telecommunications, broadcasting, electricity, automation and other industries out-door cabinet, IDC room cooling needs.
 
Features:
1. Reasonable energy-saving design, than common air conditioning to save 20-30% of the energy consumption
2. There are constant temperature and humidity function, high winds, to meet the needs of professional computer room.
3. Using stable vortex compressor, long service life of the product.
4. Password protection, ultra wide input voltage design.
5. Equipped with standard monitoring interface, the host and the standby machine function on duty by turns.
6. Network management function, configuration standard RS485 monitoring interface, provide standard communication protocol.

Inrow Air Conditioner Applicable Fields:
1. Mobile base station.
2. Outdoor rooms.
3. Satellite ground station.
4. Paging machine room.
5. Network management center.
6. Small computer room.
7. Small laboratory.
8. Wine cellar, etc

Service Room Dx Inrow Air Conditioner