500kw Air Dry Cooler Radiator Data Center Bitcoin Miner

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 12 Months
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (20)
  • 500kw Air Dry Cooler Radiator Data Center Bitcoin Miner
  • 500kw Air Dry Cooler Radiator Data Center Bitcoin Miner
  • 500kw Air Dry Cooler Radiator Data Center Bitcoin Miner
  • 500kw Air Dry Cooler Radiator Data Center Bitcoin Miner
  • 500kw Air Dry Cooler Radiator Data Center Bitcoin Miner
  • 500kw Air Dry Cooler Radiator Data Center Bitcoin Miner
Find Similar Products

Basic Info.

Model NO.
SHSL-D4-591-12x800
Type
Air-Cooled
Cooling Water
Industrial Water
System Type
Open System
Fans Species
Frequency Fan
Noise Level
Ultra Low
Application Fields
Machinery
Certification
RoHS, ISO
Condition
New
Brand Name
Shanghai Shenglin
Environment
Low Noise
Air Volume
50000 M3/H
Noise
60dB
Place of Original
Shanghai, China (Mainland)
Product Name
Dry Air Cooler
Fan
Ziehl-Abegg or Ebm
Fluid
Water and Ethylene Glycol
Condenser
Copper Tube Aluminum Fin
Case
Galvanized Steel/ Stainless Steel
Transport Package
Wooden Packing or Customized
Specification
CE, ROHS, GSG, ISO
Trademark
Shanghai Shenglin
Origin
Shanghai, China(Mainland)
HS Code
8415909000
Production Capacity
3000units/Month

Product Description

2500kW V type Dry cooler for immersion cooling bitcoin system
Project 1:                                                                  Project 2:

Country: USA                                                                                                Country: USA
Application: Bitcoin immersion cooling system                                             Application: Bitcoin immersion cooling system 
Cooling capacity: 1270kW                                                                            Cooling capacity: 117kW
Cooling medium: BC-888                                                                             Cooling medium: bitcoin fluid
Supply power: 415V/3P/60Hz                                                                      Supply power: 415V/3P/60Hz
Fan brand: Ziehl-Abegg                                                                               Fan brand: Chinese brand
500kw Air Dry Cooler Radiator Data Center Bitcoin Miner

dry air cooler Features
  1. High efficiency heat exchanger: capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany
  2. Fan: only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw.Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Air separator for each fan.
  3. We facilitate you to have a long lasting and low maintenance operation. Durable material and rigid enclosure with hard gloss powder coated finish. Protective enclosure for both manifolds and U-bends. Unit design for outdoor installation. 100% leakage tested at 31bar
dry air cooler Options:
1. Coil design refrigerant: water, oil, glycol.
  1. Multiple circuits.
  2. Sub-cooling circuits.
  3. Stainless steel or aluminum casing.
  4. Coated aluminum or copper fins.
  5. Explosion ploof motor.
  6. Customized fin spacing.
dry air cooler Application:
Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, immersion cooling bitcoin, smelting, etc.. It is suitable for all equipment which needs heat dissipation and is installed in the open air.

Solution A

For bitcoin minning farm, if use immersion cooling system,  our dry cooler is the most cost-effective way to remove heat and a necessary component of the immersion cooling system,  We designed a full range of immersion optimized dry coolers. From 5kW signle fan unit to the V-shaped 48-921kW dry coolers. Made in China, sized to your needs.

500kw Air Dry Cooler Radiator Data Center Bitcoin Miner
Solution B

For battery or ups stoage room(data center), if choose precision air conditioner to cooling the room, our dry cooler is also your ideal choice.

Like this way:


500kw Air Dry Cooler Radiator Data Center Bitcoin Miner
Solution C

For battery or ups stoage room(electronic and telecommunication equipment room),  we can design wall mount air conditioner for customers.

Like this way:

500kw Air Dry Cooler Radiator Data Center Bitcoin Miner


dry air cooler Technical parameter:
Fluid cooler SHSL-D1 series parameter(fin space 2.1mm)
Type SHSL-D1-005-1x350 SHSL-D1-006-1x350 SHSL-D1-007-1x350 SHSL-D1-009-1x450 SHSL-D1-011-1x450 SHSL-D1-013-1x450 SHSL-D1-014-1x500 SHSL-D1-017-1x500 SHSL-D1-020-1x500
Capacity Water 35ºC outdoor temp. Inlet 45ºC, KW 4.89 5.90 6.83 9.39 10.99 13.33 14.32 17.01 19.80
outlet 40ºC Y
20% Glycol Inlet 45ºC 4.72 5.69 6.69 8.90 10.61 13.05 13.91 16.11 19.29
outlet 40ºC Y
Medium Water flow M3/h 0.85 1.03 1.20 1.63 1.91 2.30 2.50 3.00 3.50
Pressure drop kPa 36.00 31.00 58.00 25.00 40 80 50 60 40
Air flow M3/h 2828 2712 2492 6199 5827 5225 8469 8168 7601
Y
Fan motor Phase 1 1 1 3 3 3 3 3 3
W 140 140 140 540 540 540 830 830 830
Y
A 0.60 0.60 0.60 1.10 1.10 1.10 1.45 1.45 1.45
Y
Fan No X φ 1x1x350 1x1x350 1x1x350 1x1x450 1x1x450 1x1x450 1x1x500 1x1x500 1x1x500
Sound pressure level dB(A) 31 31 31 43 43 43 49 49 49
Y 10m
Dimension L mm 870 870 870 1020 1020 1020 1220 1220 1220
W mm 525 525 525 625 625 625 825 825 825
H mm 797 797 797 820 820 820 870 870 870
A mm 690 690 690 840 840 840 1040 1040 1040
B mm -- -- -- -- -- -- -- -- --
C mm -- -- -- -- -- -- -- -- --
D mm 490 490 490 490 490 490 490 490 490
Inlet φ mm 3/4" 3/4" 3/4" 1" 1" 1" 1-1/4" 1-1/4" 1-1/4"
Inlet φ mm 3/4" 3/4" 3/4" 1" 1" 1" 1-1/4" 1-1/4" 1-1/4"
Product weight(empty) kg 38 42 48 55 60 67 75 82 91

Note: Standard SHSL-D1 remote radiator is vertical air discharge, for horizontal air discharge please add "H" in nomenclature, for excmple:SHSL-D1-005H-1X350

dry air cooler Technical parameter:
Dry cooler D2 series parameter(fin space 2.1mm)
Type D2-148-4x630 D2-166-4x630 D2-175-4x630 D2-228-6x630 D2-250-6x630 D2-276-6x630 D2-310-8x630 D2-343-8x630 D2-364-8x630 D2-392-10x630
Capacity Water KW 147.99 165.85 175.21 227.85 250.42 276.53 309.85 342.73 364.07 391.99
20% Et. Glycol KW 142.42 161.57 170.91 219.09 244.69 270.22 301.18 333.55 354.64 383.3
Air flow M3/h 76459 74341 72134 114686 111511 108188 152911 148675 144255 191136
Fan No. X φ 2x2x630 2x2x630 2x2x630 2x3x630 2x3x630 2x3x630 2x4x630 2x4x630 2x4x630 2x5x630
Fan motor
400/3N/50HZ
A 20.4 20.4 20.4 30.6 30.6 30.6 40.8 40.8 40.8 51.00
Sound pressure level dB(A)10m 64 64 64 66 66 66 67 67 67 68
Dimension L mm 2186 2186 2186 3250 3250 3250 4250 4250 4250 5250
H mm 1874 1874 1874 1874 1874 1874 1874 1874 1874 1874
D mm 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100
D1 mm 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000
L1 mm 963 963 963 963 963 963 963 963 963 963
L2 mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
L3 mm 1963 1963 1963 2963 2963 2963 3963 3963 3963 4963
Connections inlet φ mm 2XDN50 2XDN65 2XDN65 2XDN65 2XDN80 2XDN80 2XDN80 2XDN80 2XDN100 2XDN100
Connections onlet φ mm 2XDN50 2XDN65 2XDN65 2XDN65 2XDN80 2XDN80 2XDN80 2XDN80 2XDN100 2XDN100
Product weight(empty) kg 769 811 853 1134 1197 1261 1498 1589 1673 1864




 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier