• Closed Control Unit for Data Center Air Conditioner
  • Closed Control Unit for Data Center Air Conditioner
  • Closed Control Unit for Data Center Air Conditioner
  • Closed Control Unit for Data Center Air Conditioner
  • Closed Control Unit for Data Center Air Conditioner
  • Closed Control Unit for Data Center Air Conditioner

Closed Control Unit for Data Center Air Conditioner

After-sales Service: Online Services
Warranty: 1year
Type: Air Conditioner
Air Tube Material: Galvanized Sheet
Corrosion Durability: Ultrahigh
Operating Voltage: 380/400 VAC
Samples:
US$ 1450/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory, Trading Company
Diamond Member Since 2010

Suppliers with verified business licenses

Shanghai, China
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (19)

Basic Info.

Model NO.
GT-HFM-50
Noise Level
Low
Application Fields
Medicine
Mounting
Split
Lifetime
>20 years
Certification
RoHS, ISO, CE
Condition
New
Application
Cabinet Precision Air Conditioner
Power Source
Electrical
Management
Powerful Network Management
Voltage (V)
220/380
Performance
Cooling/Heating
Housing Material
Stainless Steel, Coated Metal
Use
Swimming Pool Heater, House, School, Sauna, Hotel
Refrigerant
R22/R134A/R417A/R407c/R404A/R410A
Installation
Freestanding
Usage
for Air Conditioner
Transport Package
Wooden Packing
Specification
ROHS, ISO
Trademark
Shenglin
Origin
Shanghai, China
HS Code
8415830000
Production Capacity
150 Unit/Month

Product Description

Closed Control Unit for Data Center Air Conditioner
Features
1. Precise and reliable
Careful design, rigorous laboratory testing, and comprehensive quality control to ensure that the unit has excellent reliability;

Parts of the world-renowned brands, ensuring high reliability and service life;

Intelligent microprocessor control system, which enables the unit is always running at its best.

2. Constant temperature and humidity
It can accurately control the temperature (accuracy ± 1 ° C), humidity (± 5%) to adapt to all-day job requirements;

The unit equipped with a frontal area of the evaporator, to reflect the amount of wind, the small enthalpy difference, to produce the greatest sensible cooling capacity, so that the indoor environment, easy to maintain the equilibrium of temperature and humidity;

3. Variety of options
The GT-HF series of standard temperature and humidity air-conditioning unit, with conventional constant temperature and humidity control is flexible, applicable to the general (conventional) constant temperature and humidity requirements of the occasion;

GT-the HFD series of ceiling temperature and humidity air conditioning units, can be installed on the ceiling applies to the room space is small or there is no dedicated room small-scale temperature and humidity region of space;

4. Other features
Variety back to the wind (on the air: The hood / duct or directly from the unit at the top of the air; Under the air: And sent to all parts of the engine room through the raised floor plenum chamber);

Configure the removable electrode humidifier, quickly produce clean steam, optional electric humidifier scene according to user requirements;

G4 level of air filters, filter effects, to meet the conventional cleanliness requirements, and can be equipped with higher cleanliness of the F8-level air filter;
Product showing

specification
GT-HFM series constant temperature and humidity precision air conditioner specification
Model GT-HFM-() 35 40 50 55 60 70 80 90
Specification Total cooling capacity kW 36.5 42.1 49.1 54.1 61 71.6 81.4 93.6
Sensible cooling capacity kW 33.8 38.4 44.3 49.8 55.5 65.1 74.7 85.1
Electric heating kW 15 18 18 18 24 24 30 30
Air volume 2* m3/h 10500 11500 13000 15500 18000 20500 22000 25000
Outlet air pressure 2* Pa 75 75 75 75 100 100 125 125
Noise 3* dB(A) 56 58 58 58 58 58 60 60
Temperature control range and accuracy ° C 18~28, ± 1
Humidity control range and accuracy % 45~70, ± 5
Power 3N-380V-50Hz
Input power 4* kW 30 38.2 39.6 40.7 52.3 56.7 66.8 74.8
Indoor unit Supply air fan type low noise centrifugal type
capacity kW 2.2 3 3 4 5.5 7.5 7.5 11
Electrode humidifier humidification volume kg/h 13 13 13 15 15 15 18 21
Electric heating capacity kW 15 18 18 18 24 24 30 30
Evaporator type Inner grooved copper tube and aluminum fin
Air filter primary efffect plate type filter
Dimension L mm 1800 1800 2000 2000 2000 2200 2200 2500
W mm 850 850 850 850 850 1080 1080 1200
H mm 2200 2200 2150 2150 2150 2350 2350 2450
Weight kg 580 610 710 750 820 900 980 1250
Outdoor unit Model GT-( )*quantity ##### WL40*1 ##### WL55*1 WL60*1 WL70*1 WL40*2 WL50*2
compressor type Totally enclosed scroll type
quantity 1 2 2 2 2 2 4 4
condenser type Inner grooved copper tube and aluminum fin
Condensing fan type Low noise axial type
capacity kW 0.75 0.55*2 0.55*2 0.55*2 0.75*2 0.75*2 0.55*4 0.55*4
Dimension L mm 980 1880 1880 1880 1880 1880 1880 1880
W mm 980 980 980 980 980 980 980 980
H mm 1234 1080 1080 1080 1234 1234 1080 1080
Weight kg 250 320 400 400 450 500 320*2 400*2
Freon 5* type R22(R407C/R410A)
control method Out balance expansion valve
Collecting pipe 6* liquid pipe`s diameter mm 15.88 (12.7) 15.88*2 (12.7*2) 15.88*2 (12.7*2) 15.88*2 (12.7*2) 15.88*2 (12.7*2) 15.88*2 (12.7*2) 15.88*4 (12.7*4) 15.88*4 (12.7*4)
gas pipe`s diameter mm 34.9 (28.6) 22.23*2 (19.05*2) 28.6*2 (22.23*2) 28.6*2 (22.23*2) 28.6*2 (22.23*2) 34.9*2 (28.6*2) 22.23*4 (19.05*4) 28.6*4 (22.23*4)
                       
1. Cooling condition: Indoor dry bulb/wet bulb: 24/17° C; Outdoor dry bulb/wet bulb: 35/24° C;
2. Air volume\static pressure are standard data, it can be designed by client  
3. Noise data is measured 3 meters far away from the units        
4. The input power means the power consumption under max condtion      
5. If freon is R410A or R407C, please noted it in the order        
6. The dimension in the brackets is for R410A`s collecting pipe      


Closed Control Unit for Data Center Air Conditioner
Closed Control Unit for Data Center Air Conditioner

 Note: for further information please send me email.

Ms. Echo Lee

Send your message to this supplier

*From: