Data Center Temperature Humidity Control Free Cooling Precision Air Conditioner

Product Details
Customization: Available
Type: Cabinet Air Conditioner
Air Tube Material: Galvanized Sheet
Still deciding? Get samples of US$ 5000/Piece
Request Sample
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (20)
  • Data Center Temperature Humidity Control Free Cooling Precision Air Conditioner
  • Data Center Temperature Humidity Control Free Cooling Precision Air Conditioner
  • Data Center Temperature Humidity Control Free Cooling Precision Air Conditioner
  • Data Center Temperature Humidity Control Free Cooling Precision Air Conditioner
  • Data Center Temperature Humidity Control Free Cooling Precision Air Conditioner
  • Data Center Temperature Humidity Control Free Cooling Precision Air Conditioner
Find Similar Products

Basic Info.

Model NO.
GT-HFM50
Operating Voltage
380/400 VAC
Noise Level
Ordinary
Application Fields
Data Center Room
Mounting
Floor Standing
Lifetime
15~20 years
Certification
RoHS, ISO, CE
Condition
New
Name
Precision Air Conditioner
Size
Customized
Weight
Customized
Colour
Customized
Capacity
7.5-95kw
Usage
Data Centre,Computer Room, Serve Room
Material
Stainless Steel
Transport Package
Wooden Packing
Specification
CE, ISO
Trademark
Shenglin
Origin
Shanghai, China
HS Code
84158220
Production Capacity
5000PCS/Year

Product Description

Data Center Temperature Humidity Control Free Cooling Precision Air Conditioner

Precision air conditioner

Features
1.Cooling capacity: 7.5KW-93.6KW
2.Refrigerant: R22(R407C/R410A)
3.Digital control mode, can reach high accuracy.
4.Keep the dust, oil fog and moisture from entering the internal of the equipments.
5.The structure design makes the installation more flexible. And the unit can be installed perfectly in the side or outside wall of the equipment.
6.Totally solve dust and moisture contamination issues caused by ventilation.
7.Widely used in telecommunications, broadcasting, electricity, automation and other industries out-door cabinet, IDC room cooling needs.
 
 
Technical Data
GT-HFM series constant temperature and humidity precision air conditioner specification 1
Model GT-HFM-() 07 12 15 18 20 24 27 30
Specification Total cooling capacity kW 7.5 12.6 15.3 18.6 21.8 24.2 27.5 31.8
Sensible cooling capacity kW 6.9 11.7 14.1 17.4 20.2 22.4 25 29.5
Electric heating kW 3 6 6 9 9 9 12 15
Air volume 2* m3/h 1800 3250 4100 5200 5400 6600 7500 9000
Outlet air pressure 2* Pa 25 25 25 50 50 75 75 75
Noise 3* dB(A) 54 54 55 56 56 56 56 56
Temperature control range and accuracy ºC 18~28,±1
Humidity control range and accuracy % 45~70,±5
Power 3N-380V-50Hz
Input power 4* kW 6 11 12.6 16.8 17.5 19 23.9 28.9
Indoor unit Supply air fan type low noise centrifugal type
capacity kW 0.32 0.55 0.75 1.1 1.1 1.5 2.2 2.2
Electrode humidifier humidification volume kg/h 3 3 5 5 5 8 8 8
Electric heating capacity kW 3 6 6 9 9 9 12 15
Evaporator type Inner grooved copper tube and aluminum fin
Air filter primary efffect plate type filter
Dimension L mm 950 1200 1200 1200 1200 1600 1600 1600
W mm 580 680 680 680 680 780 780 780
H mm 1800 1880 1880 1880 1880 2000 2000 2200
Weight kg 190 230 270 290 300 400 430 510
Outdoor unit Model GT-( )*quantity WL08*1 WL12*1 WL15*1 WL18*1 WL20*1 WL25*1 WL27*1 WL30*1
compressor type Totally enclosed scroll type
quantity 1 1 1 1 1 1 1 1
condenser type Inner grooved copper tube and aluminum fin
Condensing fan type Low noise axial type
capacity kW 0.37 0.37 0.37 0.55 0.55 0.55 0.75 0.75
Dimension L mm 800 850 850 980 980 980 980 980
W mm 800 850 850 980 980 980 980 980
H mm 980 1080 1080 1080 1080 1080 1234 1234
Weight kg 90 120 150 170 170 205 210 220
Freon 5* type R22(R407C/R410A)
control method Out balance expansion valve
Collecting pipe 6* liquid pipe`s diameter mm 9.52(9.52) 12.7(9.52) 12.7(9.52) 15.88 (12.7) 15.88 (12.7) 15.88 (12.7) 15.88 (12.7) 15.88 (12.7)
gas pipe`s diameter mm 15.88(12.7) 19.05(15.88) 19.05 ( 15.88) 22.23 (19.05) 22.23 (19.05) 28.6 (22.23) 28.6 (22.23) 28.6 (22.23)
Data Center Temperature Humidity Control Free Cooling Precision Air Conditioner
Data Center Temperature Humidity Control Free Cooling Precision Air Conditioner
Data Center Temperature Humidity Control Free Cooling Precision Air Conditioner
Data Center Temperature Humidity Control Free Cooling Precision Air Conditioner
Data Center Temperature Humidity Control Free Cooling Precision Air Conditioner
Data Center Temperature Humidity Control Free Cooling Precision Air Conditioner



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier