Heat Recovery Floor Standing Air Handling Unit/Ahu

Product Details
Customization: Available
Type: Air Handling Unit
Air Tube Material: Galvanized Sheet
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (20)
  • Heat Recovery Floor Standing Air Handling Unit/Ahu
  • Heat Recovery Floor Standing Air Handling Unit/Ahu
  • Heat Recovery Floor Standing Air Handling Unit/Ahu
  • Heat Recovery Floor Standing Air Handling Unit/Ahu
  • Heat Recovery Floor Standing Air Handling Unit/Ahu
  • Heat Recovery Floor Standing Air Handling Unit/Ahu
Find Similar Products

Basic Info.

Model NO.
GT-ZKW-76
Corrosion Durability
Higher
Operating Voltage
380/400 VAC
Noise Level
Low
Application Fields
Heating/Cooling
Mounting
Floor Standing
Lifetime
>20 years
Certification
RoHS, CE
Condition
New
Air Volume(M³/H)
22000
Outlet Air Pressure(PA)
750
Supply Fan Capacity(Kw)
1.1
Cooling Rows
4
Return Air(Kw)
12.2
Water Flow(M³/H)
2.2
Pipe Diameter (Dn)
2.5
Color
Optional
Brand
Shenglin
Fresh Air(Kw)
22
Transport Package
Packing Customized
Specification
CE, ROHS, GSG
Trademark
Shenglin
Origin
Shanghai, China(Mainland)
HS Code
8486901000
Production Capacity
5000units / Month

Product Description

Heat Recovery Floor Standing Air Handling Unit/Ahu
Heat Recovery Floor Standing Air Handling Unit/ahu


A Central Station Air-Handling Unit is a factory-made encased assembly consisting of a fan or fans and other necessary equipment to perform one or more of the functions of circulating, cleaning, heating, cooling, humidifying, dehumidifying and mixing of air; and shall not contain a source of cooling or heating other than gas or electric heat.
 

Our product is as the following series and products

1.BMCW Module type  water cooled chiller
2.BSW Screw water cooling chillers
3. Efficient energy-saving supernormal system
4.Module type air cooled hot water unit
5.Screw type water source heat pump 
6. BAH type air handing unit
7.BMAH-B combined air handing unit
8.BMAH serire combined air handing unit SFC fan coils
9. air handing unit of clean operation room
10.air handing unit for  heat recycle type
11. air handing unit for medical and biological purification

 
Function
1.Two-way ventilation function: achieve two-way air exchange indoor and outdoor,take the outdoor fresh air into the room. While indoor polluted air let out the room,create new healthy green air-conditioning for you.
2.Efficient heat recovery efficiency of energy recovery can be built to complete the whole heat or sensible heat recovery, heat recovery efficiency of the whole is greater than 70%, significantly greater than 63% heat recovery efficiency, reduce energy consumption required for processing of fresh air for efficient energy saving.
3.Low Noise Design: built-in special low-noise air-conditioning fan, the machine housing wall covered with new sound-absorbing material, all quiet design, human embodiment of air conditioning super design.
4.Air filtration and purification functions: a coarse, medium and high efficiency filters available to prevent dust and other pollutants into the room, creating a clean environment.

 
F
eatures 
 1.Environmental protection product, with water as refrigerants, excluding freon, without any pollution of atmosphere,really achieve environmental protection.
 2.Set ventilation, take a breath,cooling, dustproof, except taste at a suit, increase air oxygen levels and improve work efficiency.
 3.Big air volume, supply of distance. Can connect piping realize post cooling air supply.
 4.Aluminum alloy (aluminous model) framework profiles, beautiful appearance, surface coatings. Sandwich filling polystyrene foam material within a polyurethane foam materials,insulation or good performance


Main features 
 1 Environmental protection product, with water as refrigerants, excluding freon, without any pollution of atmosphere,really achieve environmental protection.
 2 Set ventilation, take a breath,cooling, dustproof, except taste at a suit, increase air oxygen levels and improve work efficiency.
 3 Big air volume, supply of distance. Can connect piping realize post cooling air supply.
 4 Aluminium alloy (aluminous model) framework profiles, beautiful appearance, 30-50 thick with double panel, surface coatings. Sandwich filling polystyrene foam material within a polyurethane foam materials,insulation or good performance

 
Factory advantage:
 
1.We Shanghai Shenglin are the mature manufacture more than 15 years experience for air handing unit,rooftop air conditioner,precision air conditioner,heat pump
2.Efficient management and  strict quality control.
3.More than 20 R&D engineers.
4.Supply ability 10000 PCS per month

 
Technical Data:
Chilled Water Air Handing Unit Spec. No. 1
Model GT-ZKW- 20 40 60 80 100 150 200 250 300
Air volume(m³/h) 2000 4000 6000 8000 10000 15000 20000 25000 30000
Outlet air pressure(pa) 300 300 400 500 500 600 750 750 750
Supply fan capacity(kw) 1.1 1.5 2.2 4 5.5 11 15 15 18.5
Cooling 4 Rows Return air(kw) 12.2 23.9 35.9 48 60 90 120 150 179
water flow(m³/h) 2.2 4.2 6.1 8.2 10.5 15.3 20.4 23.8 28.2
all fresh air(kw) 22 43.8 62 90 112 156 210 265 310
water flow(m³/h) 3.8 7.7 11 15.5 19.2 27.3 36.5 45.8 55
pipe diameter (DN) 25 32 40 40 40 50 65 65 80
6 Rows Return air(kw) 17 30.1 45.2 60 75 113 151 188 210
water flow(m³/h) 2.8 5.3 7.7 10.5 13.6 19.2 25.5 30.2 36
all fresh air(kw) 30.5 58 88 118 150 200 288 355 420
water flow(m³/h) 5.1 10 15.2 20.2 26.2 35.5 49 70 72.5
pipe diameter (DN) 32 32 40 40 50 65 65 80 80
8 Rows Return air(kw) 18.3 35.2 53 70 90 132 176 220 264
water flow(m³/h) 3.2 6.2 8.9 12.2 16.2 22.2 30.2 37.2 44.2
all fresh air(kw) 34.8 70 101 138 178 245 332 410 500
water flow(m³/h) 5.8 12 17.5 23.5 30.8 42.5 57.1 71 85
pipe diameter (DN) 32 32 40 40 50 65 65 80 80
Heating 2 Rows Return air(kw) 20 42 60 84 108 150 200 250 300
water flow(m³/h) 0.8 1.9 2.6 3.7 4.6 6.5 8.7 11 13
all fresh air(kw) 18 38 54 70 100 125 180 210 280
water flow(m³/h) 0.8 1.7 2.4 3.2 4.5 5.5 7.8 10 12
pipe diameter (DN) 25 32 40 40 40 40 50 50 65
4 Rows Return air(kw) 28 56 80 110 140 200 250 320 380
water flow(m³/h) 1.2 2.4 3.5 4.8 6.3 9 11 13.5 18.2
all fresh air(kw) 32 62 90 125 150 220 300 380 450
water flow(m³/h) 1.5 2.7 3.8 5.4 6.8 9.5 13.5 16.2 19.5
pipe diameter (DN) 32 32 40 40 40 50 50 65 65
Function section
outside dimension
Mixing section Length(mm) 500 500 500 550 600 800 800 800 800
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Pre-filter section Length(mm) 100 100 100 100 100 100 100 100 100
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Medium efficiency filter section Length(mm) 500 500 500 500 500 500 500 500 500
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Cooling coil section Length(mm) 600 600 700 700 700 800 800 1000 1000
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Heating section Length(mm) 300 300 300 400 400 400 400 400 400
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Humidifying section Length(mm) 400 400 400 400 400 400 400 400 400
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Fan section Length(mm) 500 500 900 400 1100 1400 1600 1700 1850
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Current balance section Length(mm) 400 400 500 900 500 600 600 600 700
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Sound deadening section Length(mm) 800 800 800 500 800 1000 1000 1000 100
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Air outlet section Length(mm) 400 400 400 800 500 600 600 800 800
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200

Application of air handling unit
The units are widely used in the air system of many inductries like mechanical ,electronic, textile,medical,chemical,energy and foo inductries ,etc. the units are also ideal solution for restaurants, office buildings,hospitals,theaters,supermarkets and palaestra.

Any interest, freely contact us.
That would be great helpful for both of us to step further.


Heat Recovery Floor Standing Air Handling Unit/AhuHeat Recovery Floor Standing Air Handling Unit/AhuHeat Recovery Floor Standing Air Handling Unit/Ahu


   

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier