Advanced Server Immersion Cooling System with Efficient Cdu

Product Details
Customization: Available
After-sales Service: Online Support
Warranty: 1 Year
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (20)
  • Advanced Server Immersion Cooling System with Efficient Cdu
  • Advanced Server Immersion Cooling System with Efficient Cdu
  • Advanced Server Immersion Cooling System with Efficient Cdu
  • Advanced Server Immersion Cooling System with Efficient Cdu
  • Advanced Server Immersion Cooling System with Efficient Cdu
  • Advanced Server Immersion Cooling System with Efficient Cdu
Find Similar Products
  • Overview
  • Company Profile
  • Product Description
Overview

Basic Info.

Model NO.
SHSL-100W
Type
Water-Cooled
Cooling Water
Dry Cooler
System Type
Closed System
Fans Species
Double-speed fan
Noise Level
Low
Application Fields
Mining Farms and Data Center
Certification
ISO, CE
Condition
New
Capacity
600 Kw
Power
400/3n/50Hz/60Hz
Product Name
Cdu
Material
SS304, SS316L
Heat Exchanger
Within Plate Heat Exchanger
Pump
Variable Frequency Water Pump
Transport Package
Export Packaging
Specification
811kg
Trademark
SHENGLIN
Origin
Shanghai, China
HS Code
8415901000
Production Capacity
3000units/Month

Packaging & Delivery

Package Size
120.00cm * 80.00cm * 220.00cm
Package Gross Weight
680.000kg

Product Description

Company Profile

Established in 2009, Shanghai Shenglin M&E Technology Co., Ltd. is a premier enterprise focusing on the innovative design, cutting-edge research, and advanced manufacturing and sales of HVAC refrigeration equipment. Our expertise and commitment to quality have positioned us as a leader in the industry.
Shanghai Shenglin is at the forefront of high-tech innovation, pioneering liquid cooling technologies that incorporate dry coolers as the pivotal component. These solutions are indispensable for cooling high-density computing environments like supercomputers, data centers, IDC rooms, and telecommunications facilities. Our systems not only drastically cut energy consumption but also enhance operational efficiency, making significant contributions to the burgeoning fields of new energy, information technology, and the expansive Internet landscape.

Advanced Server Immersion Cooling System with Efficient Cdu
Product Description

Introduction of Coolant Distribution Unit (CDU)

The Coolant Distribution Unit (CDU) is indispensable for ensuring optimum coolant distribution within cutting-edge water cooling systems. This pivotal component guarantees smooth operation, bolstered by essential auxiliary monitoring devices and critical elements such as robust circulating pumps, efficient heat exchangers, precise electric control valves, advanced sensors, reliable filters, versatile expansion tanks, accurate flow meters, and seamless online replenishment. The unit's comprehensive factory pre-installation significantly reduces the time required for on-site setup, ensuring you get up and running with minimal delay.

Advanced Server Immersion Cooling System with Efficient Cdu
Performance Range of Coolant Distribution Unit (CDU)

Heat Transfer Capacity: Ranges from an efficient 9 kW to a powerful 1500 kW, accommodating a wide variety of operational needs.


Coolant Distribution Unit (CDU) type

1. Cabinet Coolant Distribution Unit (CDU): Engineered for precision and efficiency, designed to seamlessly fit into varying operational environments.
2. Rack Liquid to Liquid Coolant Distribution Unit (CDU): Innovatively designed for maximum efficiency in liquid-to-liquid cooling processes.
2. Rack Air to Liquid Coolant Distribution Unit (CDU): Expertly crafted to facilitate superior air-to-liquid cooling performance.


Picture of Coolant Distribution Unit (CDU)
Advanced Server Immersion Cooling System with Efficient Cdu

Technical Parameter of Coolant Distribution Unit (CDU)
Model 090W
supply power 380V 3Ph 50Hz  
Unit performance parameters
Primary side temp. Secondary side temp.  cooling capacity- 91.8
kW
Secondary side flow rate-m3/h 11.24
Secondary side pressure drop-kPa 58.9
Primary side flow rate-m3/h 11.24
Primary side pressure drop-kPa 68.9
Rated power  -kW 1.25
FLA-A 2.91
Primary side medium Softened water, ethylene glycol solution
Secondary side medium Deionized water, ethylene glycol solution, propylene glycol solution
Primary side pipeline DN50
Secondary side pipeline DN50
Interface type Chuck interface
Width  -mm 600
Deep - mm 1200
Height - mm 2000
Weight - kg 260


Cold source of Coolant Distribution Unit (CDU)
 

Air discharge direction

Advanced Server Immersion Cooling System with Efficient Cdu

Performance ranges

Cooling capacity: from 5 to 649 kw
Air volume: from 2828 to 263503 m3/h
Sound pressure level: from 31 to 69 dB A(10m)
Fluid coolers:customized on demand

High efficiency heat exchanger

Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan.
Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition).
Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany

Fan

Only choose low specific energy consumption fans.
Fan nozzle designs for maximum air flow and air throw.
Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting.
Motor: protection class IP 54 and insulation class F.
Voltage:400V/3N/50Hz
Air separator for each fan.

Testing

Heat exchangers are supplied clean and tested at a pressure of 30 bars

Options

Coil design refrigerant: water, oil, glycol.
Multiple circuits.
Sub-cooling circuits.
Stainless steel or aluminum casing.
Coated aluminum or copper fins.
Explosion ploof motor.
Customized fin spacing.


Cold source of Coolant Distribution Unit (CDU)

Fluid cooler SHSL-D1 series parameter (fin space 2.1mm): This sophisticated series is engineered for high efficiency and durability, designed to meet demanding cooling requirements.

Type

SHSL-D1-005-1x350

SHSL-D1-006-1x350

SHSL-D1-007-1x350

SHSL-D1-009-1x450

SHSL-D1-011-1x450

SHSL-D1-013-1x450

SHSL-D1-014-1x500

SHSL-D1-017-1x500

SHSL-D1-020-1x500

Capacity

Water

35ºC outdoor temp.

Inlet

45ºC,

KW

4.89

5.90

6.83

9.39

10.99

13.33

14.32

17.01

19.80

outlet

40ºC

Y

20% Glycol

Inlet

45ºC

4.72

5.69

6.69

8.90

10.61

13.05

13.91

16.11

19.29

outlet

40ºC

Y

Medium

Water flow

M3/h

0.85

1.03

1.20

1.63

1.91

2.30

2.50

3.00

3.50

Pressure drop

kPa

36.00

31.00

58.00

25.00

40

80

50

60

40

Air flow

M3/h

2828

2712

2492

6199

5827

5225

8469

8168

7601

Y

Fan motor

Phase

1

1

1

3

3

3

3

3

3

W

140

140

140

540

540

540

830

830

830

Y

A

0.60

0.60

0.60

1.10

1.10

1.10

1.45

1.45

1.45

Y

Fan

No X φ

1x1x350

1x1x350

1x1x350

1x1x450

1x1x450

1x1x450

1x1x500

1x1x500

1x1x500

Sound pressure level

dB(A)

31

31

31

43

43

43

49

49

49

Y

10m

Dimension

L

mm

870

870

870

1020

1020

1020

1220

1220

1220

W

mm

525

525

525

625

625

625

825

825

825

H

mm

797

797

797

820

820

820

870

870

870

A

mm

690

690

690

840

840

840

1040

1040

1040

B

mm

--

--

--

--

--

--

--

--

--

C

mm

--

--

--

--

--

--

--

--

--

D

mm

490

490

490

490

490

490

490

490

490

Inlet φ

mm

3/4"

3/4"

3/4"

1"

1"

1"

1-1/4"

1-1/4"

1-1/4"

Inlet φ

mm

3/4"

3/4"

3/4"

1"

1"

1"

1-1/4"

1-1/4"

1-1/4"

Product weight(empty)

kg

38

42

48

55

60

67

75

82

91


Note: The standard SHSL-D1 remote radiator is configured for vertical air discharge. Should horizontal air discharge be required, simply add 'H' in the nomenclature, for example: SHSL-D1-005H-1X350, to customize your configuration.

Our factory - Advanced equipment: Our state-of-the-art facility is equipped with the latest technology to ensure the highest standards of production.

Advanced Server Immersion Cooling System with Efficient Cdu



Client visiting us: We welcome clients from around the world to visit our facilities and witness firsthand the advanced processes and technologies we employ.

Advanced Server Immersion Cooling System with Efficient Cdu

Our certificate: Our commitment to quality and excellence is demonstrated through our extensive certification portfolio.

Advanced Server Immersion Cooling System with Efficient Cdu




FAQ

Q1. Are you a manufacturer or Trade Company?

We are a manufacturing powerhouse capable of fulfilling OEM orders, bringing your vision to life with precision and expertise.

Q2. What's the order process?

1) Inquiry-Provide us with all your clear, detailed requirements to start the process.

2) Quotation-Receive an official quotation list, meticulously detailed with all specifications for clarity and transparency.

3) PI-Confirm all technical data and pricing for the order to align expectations and project scopes.

4) Payment Terms-Secure your order with a T/T deposit in advance, ensuring a smooth transaction.

5) Production-Enter mass production with our skilled team ensuring every detail is crafted to perfection.

6) Shipping-Delivered by sea, with detailed packaging pictures provided for your assurance.

7) After-sales Service-Our dedicated team strives to assist you with any queries, ensuring satisfaction and continuous support.

Q3. How to get a prompt quotation?

When sending your inquiry, please kindly include the following crucial technical information for a swift response.

A. Function: Cooling? Confirm the primary function to tailor solutions to your specific needs.

B. Capacity: Specify the required capacity in KW or Ton to ensure optimal performance alignment.

C. Medium: Indicate the medium used, such as BC-888 or water, to fine-tune our offerings.

D. Voltages and Frequency: Specify the required voltage and frequency (V/PH/HZ) to match your operational parameters.

E. Application: Define the application to facilitate precise solution customization.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier