Rack-Mounted Cdu for Data Center Cooling
The Coolant Distribution Unit (CDU) is the central component of the water cooling system, responsible for efficiently distributing the cooling medium to meet the cooling needs of various applications. It ensures the system operates stably by incorporating additional monitoring and support devices. The CDU on the secondary side of the heat exchange unit is primarily used for controlling heat exchange in liquid cooling heat sink systems. This system includes a frequency conversion circulating pump, plate heat exchanger, electric control valve, temperature sensor, pressure sensor, filter, expansion tank, flow meter, and online liquid replenishment function. It is pre-installed and tested at the factory to reduce on-site workloads.
Performance range
· Heat transfer quantity:350~1500kW
Complete CDU System technical parameter | ||||||||
20-80KW CDU technical parameters | ||||||||
Indoor unit models | CDU020W | CDU030W | CDU040W | CDU050W | CDU060W | CDU070W | CDU080W | |
main power supply | 220V/1Ph/50Hz | |||||||
Unit performance parameters | ||||||||
Primary side 35/42 ° C Secondary side 40/47 ° C |
Heat exchange capacity-kw | 21.1 | 32.2 | 41.3 | 53.2 | 62.5 | 70.6 | 82.1 |
Secondary side flow rate - m3/h | 2.58 | 3.94 | 5.06 | 6.51 | 7.65 | 8.64 | 10.05 | |
Primary side flow rate - m3/h | 2.58 | 3.94 | 5.06 | 6.51 | 7.65 | 8.64 | 10.05 | |
Rated power of the unit - kW | 0.46 | 0.59 | 0.73 | 0.83 | 0.91 | 1.00 | 1.13 | |
Unit FLA-A | 4.26 | 4.26 | 4.26 | 5.97 | 5.97 | 5.97 | 8.81 | |
Primary side 35/45 ° C, Secondary side 40/50 ° C |
Heat exchange capacity-kw | 17.1 | 26.1 | 33.5 | 43.1 | 50.6 | 57.2 | 66.5 |
Primary side medium | Softened water, ethylene glycol solution | |||||||
Secondary side medium | Deionized water, coolant | |||||||
Performance parameters of circulating pump | ||||||||
circulating pump qty | 1 or 1+1 redundancy | |||||||
Rated power of circulating pump - kW | 0.41 | 0.54 | 0.68 | 0.78 | 0.86 | 0.95 | 1.08 | |
Connection pipe size specifications | ||||||||
Primary side pipeline | DN32 | DN32 | DN32 | DN40 | DN40 | DN40 | DN40 | |
Secondary side pipeline | DN32 | DN32 | DN32 | DN40 | DN40 | DN40 | DN40 | |
Interface type | Clamp | Clamp | Clamp | Clamp | Clamp | Clamp | Clamp | |
Unit size and weight | ||||||||
Unit width-mm | 600 | 600 | 600 | 600 | 600 | 600 | 600 | |
Unit depth-mm | 1200 | 1200 | 1200 | 1200 | 1200 | 1200 | 1200 | |
Unit height-mm | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | |
weight-kg | 200 | 200 | 200 | 200 | 200 | 200 | 200 | |
Recommended specifications for circuit breakers and cables | ||||||||
Recommended Circuit Breaker Specifications-A | 16 | 16 | 16 | 16 | 16 | 16 | 16 | |
Recommended cable specification - mm2 | 3*2.5 | 3*2.5 | 3*2.5 | 3*2.5 | 3*2.5 | 3*2.5 | 3*2.5 |
Features
· 10-inch touch screen, multi-level authority control;
· Modular design, can be increased according to the demand;
· (Optional) Double back-up high-efficiency frequency conversion pump automatically adjusts the flow rate according to the loaded condition;
· (Optional) Dual power supply backup;
· Corrosion-resistant 304 stainless steel and above material piping components;
· Standard Shenglin liquid-cooled data center function control system, temperature monitoring, secondary side temperature control, flow and differential pressure control, anti-condensation protection, conductivity monitoring (optional), water turbidity monitoring (optional), water hardness monitoring (optional), PH value monitoring (optional);
· Ultra-quiet motor, low noise, long service life;
· Standard Modbus TCP communication protocol, rich detection, alarm and protection functions in the system, automatic protection of the setup parameters, power-down will not lose the operating parameters and alarm records;
· Provide standard communication protocol, can be customized according to customer demand for special format monitoring protocol;
· Secondary side filtration precision: 25~100 (μm) ultra-wide design range.
Our Advantages
With Shenglin's cutting-edge design, the CDU enhances the efficiency and dependability of the water cooling system. It boasts six channels that link the main pipeline to the secondary water separator of the water-cooled cabinet, eliminating installation and production errors with the use of clamps and rubber hoses.
Shenglin's CDU features a multi-stage centrifugal pump for circulating industrial water, ensuring a smooth and reliable flow of coolant. An expansion tank is integrated into the CDU to compensate for temperature fluctuations, maintaining consistent pressure levels and ensuring the system's reliable operation.
To prevent issues like oxidation corrosion, inadequate circulation, and cavitation of the circulation pump, Shenglin's CDU includes an automatic air vent valve on the top of the makeup water tank/main pipeline. This valve promptly eliminates non-condensable gases from the system.
Furthermore, Shenglin's CDU is equipped with a 150μm filter in its main path to preserve the quality of the coolant, guaranteeing the steady and secure operation of the entire system.