Residential Chilled Water Air Handler/Ahu with OEM Service

Product Details
Customization: Available
Type: Air Handling Unit
Air Tube Material: Galvanized Sheet
Still deciding? Get samples of US$ 10000/Piece
Request Sample
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (20)
  • Residential Chilled Water Air Handler/Ahu with OEM Service
  • Residential Chilled Water Air Handler/Ahu with OEM Service
  • Residential Chilled Water Air Handler/Ahu with OEM Service
  • Residential Chilled Water Air Handler/Ahu with OEM Service
  • Residential Chilled Water Air Handler/Ahu with OEM Service
  • Residential Chilled Water Air Handler/Ahu with OEM Service
Find Similar Products

Basic Info.

Model NO.
Gt-Zkw-300
Corrosion Durability
Higher
Operating Voltage
380/400 VAC
Noise Level
Low
Application Fields
HVAC
Mounting
Floor Standing
Lifetime
>20 years
Certification
RoHS, ISO, CE
Condition
New
Application
Industrial Air Conditioner
Power Source
Electrical
Management
Powerful Network Management
Voltage (V)
220/380
Performance
Cooling/Heating
Housing Material
Stainless Steel, Coated Metal
Use
Swimming Pool Heater, House, School, Sauna, Hotel
Refrigerant
R22/R134A/R417A/R407c/R404A/R410A
Installation
Freestanding
Usage
for Air Conditioner
Transport Package
Wooden Packing
Specification
CE
Trademark
Shenglin
Origin
Shanghai, China(Mainland)
HS Code
8415830000
Production Capacity
5000PCS/Year

Product Description

 Air Handler Features:
1, Complying with above China Standard, which is from ARI standard. ISO9001 and ISO14001 qualified.
2, Choose best materials, main components are from China top brand or imported.
3, The modular casing design, easy interchanging each other. easy install,easy transport,easy maintaince.
4, Unique no-cold-bridge design, improve the insulation and air tightness, total air leak rate ≤2.5%;
5, With dynamic balanced double inlet Centrifugal fan, with good air dynamic features, and accurate working, high efficiency, low vibration, low noise etc.
6, High efficient heat exchanger coil, ensure to provide the enough cooling capacity to the unit. And also high efficient breakwater panel is provided if required, water flow in coil ≤3×10-4kg/kg
7, Strong structure, good looking and permanent color.
8, Reasonable inside structure, with the suitable space for maintenance and cleaning.
9, Casing sheet: Provide double-skin construction constructing Sandwich type comprising 0.5mm thick galvanized internal and external skins and with 30mm thick polystyrene insulation of minimum 45kg/m3 density. Good airproof material is use between the casing and the frame to reduce the rate of the air leak.
The combined air handling untis are modular designed ,each modular can be used independently and can also work together and company with fan coil units to add refresh air. Not only reduce operation costs and energy saving, but also optimize air quality and create a congnitive indoor space to meet the human health requirements
Pictures showing
 Air Handler pictures: 
Residential Chilled Water Air Handler/Ahu with OEM Service
Residential Chilled Water Air Handler/Ahu with OEM Service
Residential Chilled Water Air Handler/Ahu with OEM Service
Residential Chilled Water Air Handler/Ahu with OEM Service
Residential Chilled Water Air Handler/Ahu with OEM Service



 Air Handler Specification:


Chilled Water Air Handing Unit Spec. No. 1
Model GT-ZKW- 20 40 60 80 100 150 200 250 300
Air volume(m³/h) 2000 4000 6000 8000 10000 15000 20000 25000 30000
Outlet air pressure(pa) 300 300 400 500 500 600 750 750 750
Supply fan capacity(kw) 1.1 1.5 2.2 4 5.5 11 15 15 18.5
Cooling 4 Rows Return air(kw) 12.2 23.9 35.9 48 60 90 120 150 179
water flow(m³/h) 2.2 4.2 6.1 8.2 10.5 15.3 20.4 23.8 28.2
all fresh air(kw) 22 43.8 62 90 112 156 210 265 310
water flow(m³/h) 3.8 7.7 11 15.5 19.2 27.3 36.5 45.8 55
pipe diameter (DN) 25 32 40 40 40 50 65 65 80
6 Rows Return air(kw) 17 30.1 45.2 60 75 113 151 188 210
water flow(m³/h) 2.8 5.3 7.7 10.5 13.6 19.2 25.5 30.2 36
all fresh air(kw) 30.5 58 88 118 150 200 288 355 420
water flow(m³/h) 5.1 10 15.2 20.2 26.2 35.5 49 70 72.5
pipe diameter (DN) 32 32 40 40 50 65 65 80 80
8 Rows Return air(kw) 18.3 35.2 53 70 90 132 176 220 264
water flow(m³/h) 3.2 6.2 8.9 12.2 16.2 22.2 30.2 37.2 44.2
all fresh air(kw) 34.8 70 101 138 178 245 332 410 500
water flow(m³/h) 5.8 12 17.5 23.5 30.8 42.5 57.1 71 85
pipe diameter (DN) 32 32 40 40 50 65 65 80 80
Heating 2 Rows Return air(kw) 20 42 60 84 108 150 200 250 300
water flow(m³/h) 0.8 1.9 2.6 3.7 4.6 6.5 8.7 11 13
all fresh air(kw) 18 38 54 70 100 125 180 210 280
water flow(m³/h) 0.8 1.7 2.4 3.2 4.5 5.5 7.8 10 12
pipe diameter (DN) 25 32 40 40 40 40 50 50 65
4 Rows Return air(kw) 28 56 80 110 140 200 250 320 380
water flow(m³/h) 1.2 2.4 3.5 4.8 6.3 9 11 13.5 18.2
all fresh air(kw) 32 62 90 125 150 220 300 380 450
water flow(m³/h) 1.5 2.7 3.8 5.4 6.8 9.5 13.5 16.2 19.5
pipe diameter (DN) 32 32 40 40 40 50 50 65 65
Function section
outside dimension
Mixing section Length(mm) 500 500 500 550 600 800 800 800 800
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Pre-filter section Length(mm) 100 100 100 100 100 100 100 100 100
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Medium efficiency filter section Length(mm) 500 500 500 500 500 500 500 500 500
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Cooling coil section Length(mm) 600 600 700 700 700 800 800 1000 1000
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Heating section Length(mm) 300 300 300 400 400 400 400 400 400
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Humidifying section Length(mm) 400 400 400 400 400 400 400 400 400
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Fan section Length(mm) 500 500 900 400 1100 1400 1600 1700 1850
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Current balance section Length(mm) 400 400 500 900 500 600 600 600 700
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Sound deadening section Length(mm) 800 800 800 500 800 1000 1000 1000 100
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
Air outlet section Length(mm) 400 400 400 800 500 600 600 800 800
Width(mm) 950 950 1080 1250 1600 1600 2000 2200 2200
Height(mm) 980 980 1080 1250 1320 1470 1680 1880 2200
 

Chilled Water Air Handing Unit Spec. No. 2
Model GT-ZKW- 350 400 450 500 550 600 700 800 1000
Air volume(m³/h) 35000 40000 45000 50000 55000 60000 70000 80000 100000
Outlet air pressure(pa) 600 600 600 600 800 800 800 800 900
Supply fan capacity(kw) 18.5 22 220 30 30 37 37 45 55
Cooling 4 Rows Return air(kw) 180 212 240 270 300 320 380 440 540
water flow(m³/h) 32.2 38.2 42.5 48.2 53.6 54.8 66 76.3 92.8
all fresh air(kw) 360 410 456 510 570 600 720 840 1020
water flow(m³/h) 62.5 72.2 78.4 87.6 98 103.1 123.7 144.3 175.3
pipe diameter (DN) 40*2 40*2 40*2 50*2 50*2 50*2 65*2 65*2 65*2
6 Rows Return air(kw) 240 280 310 350 380 400 490 560 680
water flow(m³/h) 42.5 48.1 52.3 60 66 68.8 84.2 96.6 116.8
all fresh air(kw) 456 532 590 665 720 760 930 1060 1290
water flow(m³/h) 78.4 91.4 101 114.3 123.7 130 160 182 221.6
pipe diameter (DN) 40*2 50*2 50*2 65*2 65*2 65*2 65*2 80*2 100*2
8 Rows Return air(kw) 290 330 380 420 470 480 590 680 820
water flow(m³/h) 49.8 56.7 65.3 72.7 80.8 82.5 101.4 116.8 141
all fresh air(kw) 550 630 720 800 890 910 1120 1290 1560
water flow(m³/h) 94.5 108.3 123.7 137.5 153 156.4 192.5 221.7 268
pipe diameter (DN) 50*2 65*2 65*2 65*2 65*2 65*2 80*2 100*2 100*2
Heating 2 Rows Return air(kw) 350 400 440 490 540 560 680 780 950
water flow(m³/h) 15 17.2 18.8 21.5 24 25 30 34.2 42
all fresh air(kw) 320 360 396 440 486 500 612 700 850
water flow(m³/h) 13.6 15.8 17.4 19.3 21.3 30 26.7 30.7 37.3
pipe diameter (DN) 65 65 655 80 80 80 80 100 100
4 Rows Return air(kw) 450 520 90 660 730 760 920 1060 1280
water flow(m³/h) 19.5 22.5 25.8 29 32.2 32.5 40.2 45.8 56
all fresh air(kw) 405 470 530 594 660 680 830 950 1150
water flow(m³/h) 18.2 20.5 22.8 26.9 29 29.6 34.8 41.5 47.6
pipe diameter (DN) 80 80 80 80 100 100 100 125 125
Function section 
outside dimension
Mixing section Length(mm) 1000 1000 1000 1200 1200 1200 1200 1200 1200
Width(mm) 2300 2300 2300 2500 2700 2700 2800 3200 3500
Height(mm) 2580 2870 2870 2870 3200 3200 3200 3200 3200
Pre-filter section Length(mm) 100 100 100 100 100 100 100 100 100
Width(mm) 2300 2300 2300 2500 2700 2700 2800 3200 3500
Height(mm) 2580 2870 2870 2870 3200 3200 3200 3200 3200
Medium efficiency filter section Length(mm) 500 500 500 500 500 500 500 500 500
Width(mm) 2300 2300 2300 2500 2700 2700 2800 3200 3500
Height(mm) 2580 2870 2870 2870 3200 3200 3200 3200 3200
Cooling coil section Length(mm) 1200 1200 1200 1200 1200 1200 1200 1200 1200
Width(mm) 2300 2300 2300 2500 2700 2700 2800 3200 3500
Height(mm) 2580 2870 2870 2870 3200 3200 3200 3200 3200
Heating section Length(mm) 500 500 500 500 600 600 600 600 600
Width(mm) 2300 2300 2300 2500 2700 2700 2800 3200 3500
Height(mm) 2580 2870 2870 2870 3200 3200 3200 3200 3200
Humidifying section Length(mm) 400 400 400 400 400 400 400 400 400
Width(mm) 2300 2300 2300 2500 2700 2700 2800 3200 3500
Height(mm) 2580 2870 2870 2870 3200 3200 3200 3200 3200
Fan section Length(mm) 2000 2000 2000 2000 2200 2200 2300 2700 2700
Width(mm) 2300 2300 2300 2500 2700 2700 2800 3200 3500
Height(mm) 2580 2870 2870 2870 3200 3200 3200 3200 3200
Current balance section Length(mm) 800 800 800 800 800 800 800 1000 1000
Width(mm) 2300 2300 2300 2500 2700 2700 2800 3200 3500
Height(mm) 2580 2870 2870 2870 3200 3200 3200 3200 3200
Sound deadening section Length(mm) 1200 1200 1200 1200 1200 1400 1400 1400 1400
Width(mm) 2300 2300 2300 2500 2700 2700 2800 3200 3500
Height(mm) 2580 2870 2870 2870 3200 3200 3200 3200 3200
Air outlet section Length(mm) 1000 1000 1000 1200 1200 1500 1500 1500 1500
Width(mm) 2300 2300 2300 2500 2700 2700 2800 3200 3500
Height(mm) 2580 2870 2870 2870 3200 3200 3200 3200 3200
 

Factory showing:
Residential Chilled Water Air Handler/Ahu with OEM Service

Residential Chilled Water Air Handler/Ahu with OEM Service
Residential Chilled Water Air Handler/Ahu with OEM Service
Residential Chilled Water Air Handler/Ahu with OEM Service
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier