Liquid Cooling Coolant Distribution Unit (CDU) for Mining Farms and Data Center

Product Details
Customization: Available
After-sales Service: Online Support
Warranty: 1 Year
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (20)
  • Liquid Cooling Coolant Distribution Unit (CDU) for Mining Farms and Data Center
  • Liquid Cooling Coolant Distribution Unit (CDU) for Mining Farms and Data Center
  • Liquid Cooling Coolant Distribution Unit (CDU) for Mining Farms and Data Center
  • Liquid Cooling Coolant Distribution Unit (CDU) for Mining Farms and Data Center
  • Liquid Cooling Coolant Distribution Unit (CDU) for Mining Farms and Data Center
  • Liquid Cooling Coolant Distribution Unit (CDU) for Mining Farms and Data Center
Find Similar Products
  • Overview
  • Company Profile
  • Product Description
Overview

Basic Info.

Model NO.
SHSL-090W
Type
Water-Cooled
Cooling Water
Dry Cooler
System Type
Closed System
Fans Species
Double-speed fan
Noise Level
Low
Application Fields
Mining Farms and Data Center
Certification
ISO, CE
Condition
New
Capacity
300 Kw
Power
400/3n/50Hz/60Hz
Product Name
Cdu
Material
SS304, SS316L
Heat Exchanger
Within Plate Heat Exchanger
Pump
Variable Frequency Water Pump
Transport Package
Export Packaging
Specification
811kg
Trademark
SHENGLIN
Origin
Shanghai, China
HS Code
8415901000
Production Capacity
3000units/Month

Packaging & Delivery

Package Size
120.00cm * 80.00cm * 220.00cm
Package Gross Weight
650.000kg

Product Description

Company Profile

Shanghai Shenglin was established in 2009, mainly engaged in the design, research and manufacturing and sales of HVAC refrigeration equipment.  
Shanghai Shenglin is moving towards high-tech enterprises. Currently, it is developing liquid cooling related technologies with dry coolers as the core, which are widely used for cooling high-density computing equipment such as supercomputers, data centers, IDC rooms, and telecommunications rooms. It can significantly reduce energy consumption in related industries, improve efficiency, and has great potential in the three major fields of new energy, information, and the Internet.

Liquid Cooling Coolant Distribution Unit (CDU) for Mining Farms and Data Center
 
Product Description

Introduction of Coolant Distribution Unit (CDU)

The Coolant Distribution Unit (CDU) is essential for efficient coolant distribution in water cooling systems. It ensures stable operation through auxiliary monitoring devices and key components, including circulating pumps, heat exchangers, electric control valves, sensors, filters, expansion tanks, flow meters, and online replenishment. Factory pre-installation minimizes on-site setup time.

Liquid Cooling Coolant Distribution Unit (CDU) for Mining Farms and Data Center
Performance Range of Coolant Distribution Unit (CDU)

Heat Transfer Capacity: 9 kw~1500 kW


Coolant Distribution Unit (CDU) type

1. Cabient Coolant Distribution Unit (CDU)
2. Rack liquid to liquid Coolant Distribution Unit (CDU)
2. Rack air to liquid Coolant Distribution Unit (CDU)


Picture of Coolant Distribution Unit (CDU) 
Liquid Cooling Coolant Distribution Unit (CDU) for Mining Farms and Data Center

 Technical Parameter of Coolant Distribution Unit (CDU) 
Model 090W
supply power 380V 3Ph 50Hz  
Unit performance parameters
Primary side temp. Secondary side temp.  cooling capacity- 91.8
kW
Secondary side flow rate-m3/h 11.24
Secondary side pressure drop-kPa 58.9
Primary side flow rate-m3/h 11.24
Primary side pressure drop-kPa 68.9
Rated power  -kW 1.25
FLA-A 2.91
Primary side medium Softened water, ethylene glycol solution
Secondary side medium Deionized water, ethylene glycol solution, propylene glycol solution
Primary side pipeline DN50
Secondary side pipeline DN50
Interface type Chuck interface
Width  -mm 600
Deep - mm 1200
Height - mm 2000
Weight - kg 260


Cold source of Coolant Distribution Unit (CDU) 
 

Air discharge direction

Liquid Cooling Coolant Distribution Unit (CDU) for Mining Farms and Data Center

Performance ranges

Cooling capacity: from 5 to 649 kw
Air volume: from 2828 to 263503 m3/h
Sound pressure level: from 31 to 69 dB A(10m)
Fluid coolers:customized on demand

High efficiency heat exchanger

Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan.
Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition).
Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany

Fan

Only choose low specific energy consumption fans.
Fan nozzle designs for maximum air flow and air throw.
Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting.
Motor: protection class IP 54 and insulation class F.
Voltage:400V/3N/50Hz
Air separator for each fan.

Testing

Heat exchangers are supplied clean and tested at a pressure of 30 bars

Options

Coil design refrigerant: water, oil, glycol.
Multiple circuits.
Sub-cooling circuits.
Stainless steel or aluminum casing.
Coated aluminum or copper fins.
Explosion ploof motor.
Customized fin spacing.


Cold source of Coolant Distribution Unit (CDU) 

Fluid cooler SHSL-D1 series parameter(fin space 2.1mm)

Type

SHSL-D1-005-1x350

SHSL-D1-006-1x350

SHSL-D1-007-1x350

SHSL-D1-009-1x450

SHSL-D1-011-1x450

SHSL-D1-013-1x450

SHSL-D1-014-1x500

SHSL-D1-017-1x500

SHSL-D1-020-1x500

Capacity

Water

35ºC outdoor temp.

Inlet

45ºC,

KW

4.89

5.90

6.83

9.39

10.99

13.33

14.32

17.01

19.80

outlet

40ºC

Y

20% Glycol

Inlet

45ºC

4.72

5.69

6.69

8.90

10.61

13.05

13.91

16.11

19.29

outlet

40ºC

Y

Medium

Water flow

M3/h

0.85

1.03

1.20

1.63

1.91

2.30

2.50

3.00

3.50

Pressure drop

kPa

36.00

31.00

58.00

25.00

40

80

50

60

40

Air flow

M3/h

2828

2712

2492

6199

5827

5225

8469

8168

7601

Y

Fan motor

Phase

1

1

1

3

3

3

3

3

3

W

140

140

140

540

540

540

830

830

830

Y

A

0.60

0.60

0.60

1.10

1.10

1.10

1.45

1.45

1.45

Y

Fan

No X φ

1x1x350

1x1x350

1x1x350

1x1x450

1x1x450

1x1x450

1x1x500

1x1x500

1x1x500

Sound pressure level

dB(A)

31

31

31

43

43

43

49

49

49

Y

10m

Dimension

L

mm

870

870

870

1020

1020

1020

1220

1220

1220

W

mm

525

525

525

625

625

625

825

825

825

H

mm

797

797

797

820

820

820

870

870

870

A

mm

690

690

690

840

840

840

1040

1040

1040

B

mm

--

--

--

--

--

--

--

--

--

C

mm

--

--

--

--

--

--

--

--

--

D

mm

490

490

490

490

490

490

490

490

490

Inlet φ

mm

3/4"

3/4"

3/4"

1"

1"

1"

1-1/4"

1-1/4"

1-1/4"

Inlet φ

mm

3/4"

3/4"

3/4"

1"

1"

1"

1-1/4"

1-1/4"

1-1/4"

Product weight(empty)

kg

38

42

48

55

60

67

75

82

91


Note: Standard SHSL-D1 remote radiator is vertical air discharge, for horizontal air discharge please add "H" in nomenclature, for excmple:SHSL-D1-005H-1X350

Our factory - Advanced equipment

Liquid Cooling Coolant Distribution Unit (CDU) for Mining Farms and Data Center



Client visiting us

Liquid Cooling Coolant Distribution Unit (CDU) for Mining Farms and Data Center

Our certificate

Liquid Cooling Coolant Distribution Unit (CDU) for Mining Farms and Data Center




FAQ

Q1. Are you manufacturer or Trade Company?

We are manufacture factory and we can accept OEM order.

Q2. What's the order process?

1) Inquiry---provide us all clear requirements.

2) Quotation---official quotation list with all clear specifications.

3) PI--Confirm all the order technical data and price

4) Payment terms--- T/T deposit in advance

5) Production---mass production

6) Shipping--- by sea. Detailed picture of package will be provided.

7) After-sales Service--Any questions, we will try best to assist to solve for you.

Q3. How to get a prompt quotation?

When you send the inquiry to us, pls kindly send it with below technical information.

A. Function: Cooling?

B. Capacity: _____KW or ___Ton

C.Medium: BC-888, water or  ___

D. Voltages and Frequency : ______V/PH/HZ

E. Application:
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now